The aim of this retrospective study was to evaluate the long-term results of a Swanson type silicone prosthesis used for the first metatarsophalangeal (FMTP) joint replacement. It compares implants with and without the use of grommets.
Fifty-nine FMTP joints were replaced. The average follow-up period was 9 years. Subjective and clinical findings were scored according to the AOFAS-HMI (American Orthopedic Foot and Ankle Society-Hallux Metatarsophalangeal-Interphalangeal) score. X-ray examination was carried out by evaluation of the presence of reactive bone areas around the implant.
Ninety-five percent of patients had relief of pain. Clinical findings showed a reasonable function (range of motion >30°) in 77% of the FMTP joints. A trend for decrease in radiolucency and lytic bone was seen in areas around the implant with the use of grommets.
The prosthesis shows good results concerning pain relief and a reasonable to good function (>30° range of motion) of the FMTP joint in most patients. Reactive bone areas around the implant decreased by the use of grommets.
本回顾性研究旨在评估 Swanson 型硅酮假体用于第一跖趾关节(FMTP)置换的长期效果。它比较了使用和不使用扣眼的植入物。
59 个 FMTP 关节被置换。平均随访时间为 9 年。根据 AOFAS-HMI(美国矫形足踝协会-跖趾-趾间关节)评分,对主观和临床发现进行评分。通过评估植入物周围反应性骨区域进行 X 射线检查。
95%的患者疼痛缓解。临床发现 77%的 FMTP 关节具有合理的功能(活动度>30°)。使用扣眼时,植入物周围的透光性和溶骨性区域有减少的趋势。
该假体在大多数患者中表现出良好的止痛效果和合理到良好的功能(活动度>30°)的 FMTP 关节。使用扣眼可减少植入物周围的反应性骨区。