Biological Process and Product Development, Bristol-Myers Squibb Company, 6000 Thompson Road, East Syracuse, NY 13057, USA.
J Pharm Biomed Anal. 2012 Feb 5;59:167-72. doi: 10.1016/j.jpba.2011.09.034. Epub 2011 Oct 5.
Tris(2-carboxyethyl)phosphine (TCEP) belongs to the trialkylphosphine class of reducing agents that are widely used in research and industry. In this paper, we discuss a sensitive high-performance liquid chromatography (HPLC) method equipped with an evaporative light scattering detector (ELSD) for the determination of TCEP in pharmaceutical samples containing therapeutic protein and stabilizing additives. TCEP was first completely oxidized with hydrogen peroxide to form TCEP oxide (TCEPO). Proteins and salts were removed from the sample by solid phase extraction. TCEPO concentrations were determined by anion exchange chromatography coupled with ELSD. Because of the 1:1 oxidation stoichiometry for the reaction, the concentration of TCEP in the sample is directly proportional to the measured concentration of TCEPO. A good linearity fit of ELSD response versus TCEPO concentration was observed over the range of 20-2000 μM. The specificity, precision, accuracy, and robustness of the method were evaluated and suitable for the quantitation of TCEP in biological samples. Moreover, selective treatment with peroxide prior to solid-phase extraction may be used to determine the mass balance of TCEP species or track the oxidation rate in pharmaceutical samples.
三(2-羧乙基)膦(TCEP)属于三烷基膦类还原剂,在研究和工业中被广泛应用。本文讨论了一种灵敏的高效液相色谱(HPLC)方法,该方法配备了蒸发光散射检测器(ELSD),可用于测定含有治疗性蛋白和稳定添加剂的药物样品中的 TCEP。TCEP 首先被过氧化氢完全氧化形成 TCEP 氧化物(TCEPO)。通过固相萃取从样品中去除蛋白质和盐。TCEPO 浓度通过阴离子交换色谱与 ELSD 测定。由于反应的氧化计量比为 1:1,因此样品中 TCEP 的浓度与测量的 TCEPO 浓度成正比。ELSD 响应与 TCEPO 浓度之间观察到良好的线性拟合,范围为 20-2000 μM。该方法的特异性、精密度、准确度和稳健性得到了评估,适用于生物样品中 TCEP 的定量。此外,在固相萃取之前进行过氧化物的选择性处理,可用于测定 TCEP 物质的质量平衡或跟踪药物样品中的氧化速率。