Kosai Nik, Sutton Paul Anthony, Evans Jonathan, Varghese Joseph
Department of Surgery, Royal Bolton Hospital, Bolton, United Kingdom.
J Minim Access Surg. 2011 Jul;7(3):192-4. doi: 10.4103/0972-9941.83514.
Prosthetic mesh is now used routinely in inguinal hernia repairs, although its fixation is thought to be a potential cause of chronic groin pain. The Parietene ProGrip™ (TYCO Healthcare) mesh, which is semi-resorbable and incorporates self-fixing properties, has been shown to provide satisfactory repair in open surgery. We describe the use of this mesh in TAPP hernia repair, which has not previously been reported in the literature. A prospective study of 29 patients showed a mean operative time to be 47.6 min, with 96% of patients discharged home on the day of surgery or the day after. Visual analog pain scales (out of 10) reduced from 4 preoperatively to 0 at 6 months, and only 1 patient suffered a minor wound complication. The use of this mesh in transabdominal preperitoneal hernia repair is therefore feasible, safe, and may reduce postoperative pain.
尽管人工合成补片的固定被认为是慢性腹股沟疼痛的一个潜在原因,但目前它已被常规用于腹股沟疝修补术。Parietene ProGrip™(泰科医疗公司)补片具有半可吸收性并具备自固定特性,已证实在开放手术中能提供令人满意的修补效果。我们描述了这种补片在经腹腹膜前疝修补术(TAPP)中的应用,此前文献中尚未有相关报道。一项针对29例患者的前瞻性研究显示,平均手术时间为47.6分钟,96%的患者在手术当天或术后第一天出院。视觉模拟疼痛评分(满分10分)从术前的4分降至6个月时的0分,只有1例患者出现轻微伤口并发症。因此,这种补片用于经腹腹膜前疝修补术是可行、安全的,并且可能减轻术后疼痛。