Suppr超能文献

凝胶渗透色谱-气相色谱-负化学电离质谱法测定鱼类及鱼油补充剂中的多溴二苯醚和十氯联苯

[Determination of polybrominated diphenyl ethers and dechlorane plus in fish and fish oil supplements by gel permeation hromatography coupled with gas chromatography-negative chemical ionization mass spectrometry].

作者信息

Shi Zhixiong, Wang Yifei, Feng Jinfang, Huang Peili, Wu Yongning

机构信息

School of Public Health and Family Medicine, Capital Medical University, Beijing 100069, China.

出版信息

Se Pu. 2011 Jun;29(6):543-8. doi: 10.3724/sp.j.1123.2011.00543.

Abstract

Polybrominated diphenyl ethers (PBDEs) and dechlorane plus (DP) are two kinds of widely used organic flame retardants, and PBDE and DP residues have been found in both environment and biota. A method for the determination of 8 PBDEs and 2 DPs in fish and fish oil supplements was developed using auto gel permeation chromatography (GPC) coupled with gas chromatography-negative chemical ionization/mass spectrometry (GC-NCI/MS) in the selected ion-monitoring (SIM) mode on a 15 m capillary column. The sample added with BDE-77 and 13C12-BDE-209 as the internal standards was extracted using a Soxhlet extractor, and further purified by auto GPC and a multilayer silica gel column. The sample preparation procedure was optimized, and the characteristic ions and fragmentations of the analytes in NCI/MS were studied. The limits of detection (LODs, S/N = 3) ranged from 2.2 to 39.8 ng/kg. The average recoveries were between 71.1% and 121.4% at two spiked levels of 2 and 20 ng/g for both BDE-209 and DP and 0.2 and 2 ng/g for others with the relative standard deviations between 2.96% and 13.31%. The developed method has been successfully applied in the determination of PBDEs and DPs in several fish and fish oil supplements samples. The total PBDEs found ranged from 2.18 to 15.93 ng/g, and DP was not found. This method was validated to be accurate and sensitive for the trace analysis of PBDEs and DPs in the samples with fat.

摘要

多溴二苯醚(PBDEs)和十氯酮(DP)是两类广泛使用的有机阻燃剂,并且在环境和生物群中均已发现PBDE和DP残留。建立了一种使用自动凝胶渗透色谱法(GPC)与气相色谱 - 负化学电离/质谱联用(GC - NCI/MS),在15 m毛细管柱上采用选择离子监测(SIM)模式测定鱼类及鱼油补充剂中8种PBDEs和2种DPs的方法。以BDE - 77和13C12 - BDE - 209作为内标加入到样品中,使用索氏提取器进行提取,并通过自动GPC和多层硅胶柱进一步纯化。优化了样品制备程序,并研究了NCI/MS中分析物的特征离子和裂解情况。检测限(LODs,S/N = 3)范围为2.2至39.8 ng/kg。对于BDE - 209和DP,在2和20 ng/g两个加标水平下以及对于其他物质在0.2和2 ng/g加标水平下,平均回收率在71.1%至121.4%之间,相对标准偏差在2.96%至13.31%之间。所建立的方法已成功应用于几种鱼类及鱼油补充剂样品中PBDEs和DPs的测定。所发现的总PBDEs范围为2.18至15.93 ng/g,未发现DP。该方法经验证对于含脂肪样品中PBDEs和DPs的痕量分析准确且灵敏。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验