• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The effect of screws and pegs on the initial fixation stability of an uncemented unicondylar knee replacement.

作者信息

Kaiser A D, Whiteside L A

机构信息

DePaul Biomechanical Research Laboratory, Bridgeton, Missouri 63044.

出版信息

Clin Orthop Relat Res. 1990 Oct(259):169-78.

PMID:2208852
Abstract

Two uncemented unicompartmental tibial components were examined for initial fixation stability. A conventional design that employed a single posteriorly angled peg was compared with a new design that was held in place by cancellous bone screws. The components were implanted into the medial condyles of 12 preserved human tibiae, and a cyclic load was first applied anteromedially and then posteromedially. The screwed implants failed at significantly higher loads (1634.8 +/- 121.6 N, mean +/- standard error of the mean) than the pegged implants (1103.3 +/- 152.0 N). On application of a 19.6-N preload, the screwed implants moved significantly less than the pegged implants. Although the differences in micromotion and subsidence were not always significant, there were definite trends. The screwed implants had much lower levels of temporary and permanent displacement compared with the pegged implants for all load levels from the initial load of 245.2 N up to and including the failure load. When the motion that resulted from moving the load from the anterior position to the posterior position was examined, the screwed implant's average total motion was less than 10 microns compared with almost 135 microns for the pegged implant after the 245.2-N load cycle. For the cycle before failure, the screwed implant's average motion increased to less than 29 microns, whereas the pegged implant's average total motion was almost 354 microns. From this information it appears clear that screws provide better initial fixation stability than angled pegs for uncemented unicondylar tibial components.

摘要

相似文献

1
The effect of screws and pegs on the initial fixation stability of an uncemented unicondylar knee replacement.
Clin Orthop Relat Res. 1990 Oct(259):169-78.
2
Effects of screws and a sleeve on initial fixation in uncemented total knee tibial components.
Clin Orthop Relat Res. 1990 Oct(259):160-8.
3
Effects of fixation technique on displacement incompatibilities at the bone-implant interface in cementless total knee replacement in a canine model.固定技术对犬模型非骨水泥型全膝关节置换中骨-植入物界面位移不兼容性的影响。
J Appl Biomater. 1994 Winter;5(4):349-52. doi: 10.1002/jab.770050410.
4
The role of fixation and bone quality on the mechanical stability of tibial knee components.
Clin Orthop Relat Res. 1991 Dec(273):177-83.
5
Fixation response of two cementless tibial implants under static and fatigue compression loading.两种非骨水泥型胫骨植入物在静态和疲劳压缩载荷下的固定反应。
Technol Health Care. 2003;11(4):245-52.
6
Does a tensioning device pinned to the tibia improve knee anterior-posterior load-displacement compared to manual tensioning of the graft following anterior cruciate ligament reconstruction? A cadaveric study of two tibial fixation devices.与前交叉韧带重建术后手动张紧移植物相比,固定在胫骨上的张紧装置是否能改善膝关节前后负荷位移?对两种胫骨固定装置的尸体研究。
J Orthop Res. 2006 Sep;24(9):1832-41. doi: 10.1002/jor.20216.
7
The cemented unicondylar knee arthroplasty. An in vitro comparison of three cement techniques.
Clin Orthop Relat Res. 1992 Nov(284):215-20.
8
A new model to assess tibial fixation. II. Concurrent histologic and biomechanical observations.
Clin Orthop Relat Res. 1991 Feb(263):303-9.
9
Addition of a short central extension to surface cemented tibial trays in primary TKA: an in vitro study of the effect on initial fixation stability and its relationship to supporting bone density.初次全膝关节置换术中在表面骨水泥固定的胫骨托上增加短的中央延伸部分:对初始固定稳定性影响及其与支撑骨密度关系的体外研究
Clin Biomech (Bristol). 2008 May;23(4):483-92. doi: 10.1016/j.clinbiomech.2007.11.012. Epub 2008 Jan 2.
10
Stability of initial fixation of the tibial component in cementless total knee arthroplasty.
J Orthop Res. 1990 Jan;8(1):64-71. doi: 10.1002/jor.1100080108.