St. James's Institute of Oncology, St. James's Hospital, Leeds, UK.
Radiother Oncol. 2012 May;103(2):261-5. doi: 10.1016/j.radonc.2011.09.022. Epub 2011 Nov 16.
To investigate the relationships between the planning target volume (PTV) and the total reference air kerma (TRAK) required to irradiate the prostate using the Nucletron microSelection (192)Ir radioactive stepping source afterloader for the treatment of prostate cancer.
Using 54 patient plans, the relationship between the treatment planning system (TPS) TRAK (TRAK(TPS)) and the estimate and planimetry prostate volumes was investigated. Linear regression analysis was used to predict the TRAK (TRAK(pred)) using the prostate gland height, width and length (HWL) measurements. The TRAK was corrected using a conformal index (COIN) of the plan to improve the accuracy of the model. A further 54 patient plans were then used to evaluate the outcome of the linear regression lines.
A formula was proposed (HxWxLxπ/5.19) to estimate the prostate volume, which showed a mean deviation from the planimetry volume of 0.0139 ± 3.339 cm(3), where 69% was within ± 10% of planimetry, and 96% within ±20%. Scatter graphs of TRAK(TPS) for 54 plans, showed a positive linear correlation, r=0.98, using the planimetry volume, and r=0.95 for the estimated volume. The further 54 treatment plans used for evaluation showed the TRAK(pred) was accurately predicted to ± 10% for 100% of plans using the planimetry volume and 81% using the prostate volume estimate.
The verification method proposed was found to be accurate and independent of TPS parameters, with suitable acceptance margins of ± 10%.
研究使用 Nucletron microSelection(192)Ir 放射性步进源后装治疗前列腺癌时,前列腺靶区(PTV)与总参考空气比释动能(TRAK)之间的关系,以实现前列腺的照射。
使用 54 例患者的计划,研究了治疗计划系统(TPS)TRAK(TRAK(TPS))与前列腺体积的估算和描绘之间的关系。使用前列腺腺体高度、宽度和长度(HWL)的测量值,进行线性回归分析,预测 TRAK(TRAK(pred))。通过计划的适形指数(COIN)对 TRAK 进行校正,以提高模型的准确性。然后,使用另外 54 例患者的计划来评估线性回归线的结果。
提出了一个公式(HxWxLxπ/5.19)来估算前列腺体积,该公式与描绘体积的平均偏差为 0.0139±3.339cm3,其中 69%在描绘体积的±10%以内,96%在±20%以内。54 例计划的 TRAK(TPS)散点图显示,与描绘体积呈正线性相关,r=0.98,与估计体积呈 r=0.95。进一步用于评估的另外 54 例治疗计划显示,使用描绘体积和前列腺体积估计值,TRAK(pred)的预测值准确到±10%,分别有 100%和 81%的计划符合要求。
所提出的验证方法被发现是准确的,并且独立于 TPS 参数,具有合适的±10%的可接受范围。