The Luminex xTAG(®) respiratory viral panel (RVP) kit simultaneously detects and identifies multiple respiratory viruses including several subtypes of influenza A using a multiplex nucleic acid amplification test assay platform. The emitted fluorescence signal from the RVP assay provides qualitative information on the presence of a particular viral species in respiratory specimens. However, a quantitative assessment is preferred when monitoring environmental samples for respiratory viruses. In this study, we explored the potential use of the RVP kit as a semi-quantitative screening assay for influenza virus detection. The concentration- response of the RVP assay was modeled using four-parameter logistic (4-PL) fits of mean fluorescence intensity (MFI) versus dilute ranges of the influenza A matrix gene, seasonal influenza vaccine, and 2009 H1N1 influenza vaccine. The goodness of fit of the 4-PL model was evaluated by comparing the copy number determined with the fitted model (observed copy number) with the copy number calculated from the dilution of the matrix DNA or vaccine (expected copy number). For the matrix DNA and 2009 H1N1 vaccine, the 4-PL model provided good fit for the influenza A RVP assay response over factors of 10(3) to 10(4). For seasonal influenza vaccine, the model provided good fit for RVP assay response to influenza A, influenza B, H1, and H3.

摘要

Luminex xTAG(®)呼吸道病毒检测试剂盒(RVP)采用多重核酸扩增检测技术平台,可同时检测和鉴定多种呼吸道病毒,包括几种甲型流感亚型。RVP 检测的荧光信号发射提供了呼吸道标本中特定病毒种类存在的定性信息。然而,在监测环境样本中的呼吸道病毒时,更倾向于进行定量评估。在本研究中,我们探讨了将 RVP 试剂盒用作甲型流感病毒检测的半定量筛查检测方法的潜力。采用四参数逻辑(4-PL)拟合平均荧光强度(MFI)与甲型流感基质基因、季节性流感疫苗和 2009 年 H1N1 流感疫苗的稀释范围,对 RVP 检测的浓度-反应进行建模。通过比较拟合模型确定的拷贝数(观察拷贝数)与从基质 DNA 或疫苗稀释计算的拷贝数(预期拷贝数),评估 4-PL 模型的拟合优度。对于基质 DNA 和 2009 年 H1N1 疫苗,4-PL 模型在 10(3)到 10(4)的流感 A RVP 检测反应中提供了良好的拟合。对于季节性流感疫苗,该模型在 RVP 检测对甲型流感、乙型流感、H1 和 H3 的反应中提供了良好的拟合。

相似文献

1
Semi-quantitative analysis of influenza samples using the Luminex xTAG(®) respiratory viral panel kit.
Toxicol Mech Methods. 2012 Apr;22(3):211-7. doi: 10.3109/15376516.2011.610387. Epub 2011 Nov 23.
2
Evaluation of multiple test methods for the detection of the novel 2009 influenza A (H1N1) during the New York City outbreak.
J Clin Virol. 2009 Jul;45(3):191-5. doi: 10.1016/j.jcv.2009.06.005. Epub 2009 Jun 16.
7
Validation of the Cepheid Xpert Flu A real time RT-PCR detection panel for emergency use authorization.
J Clin Virol. 2010 Aug;48(4):234-8. doi: 10.1016/j.jcv.2010.06.001. Epub 2010 Jun 26.

引用本文的文献

本文引用的文献

1
Measurements of airborne influenza virus in aerosol particles from human coughs.
PLoS One. 2010 Nov 30;5(11):e15100. doi: 10.1371/journal.pone.0015100.
2
Evaluation of multiple test methods for the detection of the novel 2009 influenza A (H1N1) during the New York City outbreak.
J Clin Virol. 2009 Jul;45(3):191-5. doi: 10.1016/j.jcv.2009.06.005. Epub 2009 Jun 16.
4
Bioaerosol sampling for the detection of aerosolized influenza virus.
Influenza Other Respir Viruses. 2007 May;1(3):113-20. doi: 10.1111/j.1750-2659.2007.00020.x.
5
New electropositive filter for concentrating enteroviruses and noroviruses from large volumes of water.
Appl Environ Microbiol. 2009 Apr;75(8):2393-9. doi: 10.1128/AEM.00922-08. Epub 2009 Feb 13.
6
Measurement of airborne influenza virus in a hospital emergency department.
Clin Infect Dis. 2009 Feb 15;48(4):438-40. doi: 10.1086/596478.
7
xTAG RVP assay: analytical and clinical performance.
J Clin Virol. 2007 Nov;40 Suppl 1:S39-46. doi: 10.1016/S1386-6532(07)70009-4.
8
The clinical need for the RVP test.
J Clin Virol. 2007 Nov;40 Suppl 1:S36-8. doi: 10.1016/S1386-6532(07)70008-2.
9
Principles of the xTAG respiratory viral panel assay (RVP Assay).
J Clin Virol. 2007 Nov;40 Suppl 1:S31-5. doi: 10.1016/S1386-6532(07)70007-0.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验