• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Experimental and early clinical evaluation of vascular anastomoses with argon laser fusion and the use of absorbable guy sutures: a preliminary report.

作者信息

White R A, Kopchok G E, Vlasak J, Hsiang Y, Fujitani R M, White G H, Peng S K

机构信息

Department of Surgery, Harbor-UCLA Medical Center.

出版信息

J Vasc Surg. 1990 Oct;12(4):401-6; discussion 406-8.

PMID:2214036
Abstract

This study investigated the feasibility of forming vascular anastomoses by use of argon laser tissue fusion and absorbable, monofilament polydimethylsiloxane guy sutures. In initial animal studies femoral arteriovenous fistulas approximately 1.5 cm in length were created bilaterally in each of 10 dogs and were studied histologically at 2, 4, 8, 16, and 24 weeks (two animals in each interval). In each animal, one anastomosis (control) was formed with continuous 6-0 polypropylene suture, and the contralateral anastomosis (experimental) was performed with an argon laser (0.5 watt, 5 to 7 minutes exposure, energy fluence 1100 to 1500 joules/cm2 per 1 cm length) with stay sutures of 5-0 polydimethylsiloxane at 0.5 to 0.65 cm intervals. At removal, all anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 2 to 16 weeks demonstrated resorption of the biodegradable suture material by a local inflammatory reaction. By 24 weeks, laser-fused specimens had no evidence of suture material at the anastomotic line, and healing consisted of a bond between artery and vein wall tissues. Control suture specimens at the same intervals exhibited an organized fibrous tissue response to the suture. Clinical adaptability of this technology has subsequently been evaluated in five patients at 10 to 27 months (21.6 +/- 5.8) by physical examination and duplex scanning and demonstrate no evidence of abnormal healing. This study establishes the experimental and preliminary clinical feasibility of laser-fused anastomoses aligned by biodegradable guy sutures and supports further investigation and refinement of the technique.

摘要

相似文献

1
Experimental and early clinical evaluation of vascular anastomoses with argon laser fusion and the use of absorbable guy sutures: a preliminary report.
J Vasc Surg. 1990 Oct;12(4):401-6; discussion 406-8.
2
Argon laser-welded arteriovenous anastomoses.
J Vasc Surg. 1987 Nov;6(5):447-53.
3
Initial human evaluation of argon laser-assisted vascular anastomoses.氩激光辅助血管吻合术的首次人体评估。
J Vasc Surg. 1989 Apr;9(4):542-7. doi: 10.1067/mva.1989.vs0090542.
4
Side-to-side sutureless vascular anastomosis with magnets.使用磁体进行的端侧无缝合血管吻合术。
J Vasc Surg. 2004 Sep;40(3):505-11. doi: 10.1016/j.jvs.2004.05.026.
5
Nd:YAG laser-welded canine arteriovenous anastomoses.钕钇铝石榴石激光焊接犬动静脉吻合术
Lasers Surg Med. 1994;14(2):111-7. doi: 10.1002/1096-9101(1994)14:2<111::aid-lsm1900140203>3.0.co;2-f.
6
Polydioxanone and polypropylene suture material in free internal mammary artery graft anastomoses.
J Thorac Cardiovasc Surg. 1988 Nov;96(5):741-5.
7
Mechanism of tissue fusion in argon laser-welded vein-artery anastomoses.氩激光焊接静脉-动脉吻合术中组织融合的机制。
Lasers Surg Med. 1988;8(1):83-9. doi: 10.1002/lsm.1900080115.
8
Laser-fused biologic vascular graft anastomoses.激光融合生物血管移植物吻合术。
J Invest Surg. 1993 May-Jun;6(3):289-95. doi: 10.3109/08941939309141618.
9
Argon laser-welded bovine heterograft anastomoses.氩激光焊接的牛异种移植物吻合术。
J Clin Laser Med Surg. 1993 Feb;11(1):1-5. doi: 10.1089/clm.1993.11.1.
10
Laser vascular welding--how does it work?激光血管焊接——它是如何工作的?
Ann Vasc Surg. 1987 May;1(4):461-4. doi: 10.1016/S0890-5096(06)60732-2.