Walorczyk Stanislaw, Drozdzyński Dariusz
Institute of Plant Protection-National Research Institute, Władysława Wegorka 20, 60-318 Poznań, Poland.
J AOAC Int. 2011 Sep-Oct;94(5):1625-42. doi: 10.5740/jaoacint.10-329.
A GC/tandem quadrupole MS/MS method was developed and validated for the determination of the residues of 140 pesticides in fruits and vegetables. Pesticides were extracted from samples by using a miniaturized acetonitrile-based extraction technique known as the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. Validation studies were carried out on carrots, tomatoes, and strawberries. In order to reduce systematic errors due to a matrix-induced effect, quantification was carried out using matrix-matched standard calibration curves. The recovery and precision results satisfied the European Union criteria (i.e., average recoveries were in the range 70-120% with RSDs < or = 20%) for 125 of the 140 pesticides at a spiking level of 0.01 mg/kg. At the higher spiking levels, there were just two instances of overall average recovery < 70% (chlorothalonil and captan). The measurement uncertainty was estimated following a "top down" approach as being 21 and 35%, on average, based on validation and ongoing recovery data, respectively (coverage factor k = 2, confidence level 95%). Practical application to 541 samples of apples, tomatoes, strawberries, cucumbers, currants, mushrooms, carrots, peppers, pears, onions, and gooseberries under strict QC conditions demonstrated the ruggedness of the total procedure.
建立并验证了一种气相色谱/串联四极杆质谱/质谱法,用于测定水果和蔬菜中140种农药的残留量。采用一种称为快速、简便、廉价、有效、耐用和安全(QuEChERS)的基于乙腈的小型化萃取技术从样品中萃取农药。在胡萝卜、西红柿和草莓上进行了验证研究。为了减少基质诱导效应引起的系统误差,使用基质匹配标准校准曲线进行定量。在加标水平为0.01 mg/kg时,140种农药中的125种的回收率和精密度结果符合欧盟标准(即平均回收率在70-120%范围内,相对标准偏差<或=20%)。在较高加标水平下,只有两种情况的总体平均回收率<70%(百菌清和克菌丹)。根据“自上而下”的方法,基于验证和持续的回收率数据,测量不确定度估计平均分别为21%和35%(覆盖因子k = 2,置信水平95%)。在严格的质量控制条件下,对541个苹果、西红柿、草莓、黄瓜、醋栗、蘑菇、胡萝卜、辣椒、梨、洋葱和醋栗样品的实际应用证明了整个程序的耐用性。