Liu Derek, Usmani Nawaid, Ghosh Sunita, Kamal Wafa, Pedersen John, Pervez Nadeem, Yee Don, Danielson Brita, Murtha Albert, Amanie John, Sloboda Ron S
Division of Medical Physics, Cross Cancer Institute, Edmonton, Alberta, Canada.
Brachytherapy. 2012 Jul-Aug;11(4):284-91. doi: 10.1016/j.brachy.2011.11.004. Epub 2011 Dec 23.
To compare preimplant prostate contours and contouring variability between magnetic resonance (MR) and transrectal ultrasound images.
Twenty-three patients were imaged using ultrasound (US) and MR before permanent brachytherapy treatment. Images were anonymized, randomized, and duplicated, and the prostate was independently delineated by five radiation oncologists. Contours were compared in terms of volume, dimensions, posterior rectal indentation, and observer variability. The Jaccard index quantified spatial overlap between contours from duplicated images.
The mean US/MR volume ratio was 0.99±0.08 (p=0.5). The width, height, and length ratios for the prostate were 0.98±0.06 (p=0.09), 0.99±0.08 (p=0.4), and 1.05±0.14 (p=0.1). Rectal indentation was larger on US by 0.18mL (p=0.01) and correlated with prostate volume (p<0.01). MR and US interobserver variability in volume were similar at 3.5±1.7 and 3.3±1.9mL (p=0.6). Intraobserver variability was smaller on US at 1.4±1.1mL compared with MR at 2.4±2.2mL (p=0.01). Local intraobserver variability was lower on US at the midgland slice (p<0.01) but lower on MR at the base (p<0.01) and apex (p<0.01) slices.
US is comparable to MR for preimplant prostate delineation, with no significant difference in volume and dimensions. Rectal indentation because of the transrectal ultrasound probe was measurable, although the effects were small. Intraobserver variability was lower on US for the prostate volume but was lower on MR locally at the base and apex. However, the difference was not observed for the interobserver variability, which was similar between MR and US.
比较磁共振(MR)图像和经直肠超声图像在植入前前列腺轮廓及轮廓勾画的变异性。
23例患者在进行永久性近距离放射治疗前接受了超声(US)和MR成像。图像进行了匿名化、随机化和复制处理,由5名放射肿瘤学家独立勾画前列腺轮廓。从体积、尺寸、直肠后压迹和观察者变异性方面对轮廓进行比较。Jaccard指数量化了复制图像轮廓之间的空间重叠。
平均US/MR体积比为0.99±0.08(p = 0.5)。前列腺的宽度、高度和长度比分别为0.98±0.06(p = 0.09)、0.99±0.08(p = 0.4)和1.05±0.14(p = 0.1)。经直肠超声检查时直肠压迹大0.18mL(p = 0.01),且与前列腺体积相关(p<0.01)。MR和US观察者间体积变异性相似,分别为3.5±1.7和3.3±1.9mL(p = 0.6)。观察者内变异性在US上较小,为1.4±1.1mL,而在MR上为2.4±2.2mL(p = 0.01)。在腺体中部层面,观察者内局部变异性在US上较低(p<0.01),但在基底部(p<0.01)和尖部(p<0.01)层面在MR上较低。
在植入前前列腺勾画方面,US与MR相当,在体积和尺寸上无显著差异。经直肠超声探头导致的直肠压迹是可测量的,尽管影响较小。前列腺体积的观察者内变异性在US上较低,但在基底部和尖部局部在MR上较低。然而,观察者间变异性在MR和US之间相似,未观察到差异。