Suppr超能文献

儿科外周静脉置管文档记录的准确性:电子病历中的干预研究。

Accuracy in documentation of peripheral venous catheters in paediatric care: an intervention study in electronic patient records.

机构信息

Department of Women's and Children's Health, Karolinska Institutet, Stockholm and School of Health and Social Studies, Dalarna University, Falun, Sweden.

出版信息

J Clin Nurs. 2012 May;21(9-10):1339-44. doi: 10.1111/j.1365-2702.2011.03949.x. Epub 2012 Jan 14.

Abstract

AIMS

The aim of this study is to compare the accuracy and completeness in the recording of peripheral venous catheters before and after implementing a template in the electronic patient record in paediatric care.

BACKGROUND

As a basis for quality improvement and research purposes and to ensure patient safety, accurate clinical data need to be easily accessible in patient records. Several studies have concluded that the relation between performed care and what is documented in patient records is poor.

DESIGN

Before and after study.

METHOD

The study took place at a large paediatric university hospital in Sweden. Inclusion criteria were patients who were admitted to one of the included wards, had one or several peripheral venous catheters and were available at the ward at the time for data collection. Data were collected by observations and record audits before and then four and 10 months after the introduction of a template for recording peripheral venous catheters in a structured and standardised way.

RESULTS

A significant increase in peripheral venous catheters with complete recording was observed after as compared with before the intervention. The percentage of peripheral venous catheters with recording of any kind was relatively stable (85-93%). The overall recording of peripheral venous catheters insertion did not improve, but there was an increase in the recording of side and size after the intervention. One of the 22 complications observed before the intervention was documented and none of the complications (n = 17 and n = 9) after.

CONCLUSION

The electronic patient record did not provide accurate data on peripheral venous catheters in paediatric care neither before nor after the intervention.

RELEVANCE TO CLINICAL PRACTICE

Further efforts to increase the documentation of catheter-related complications are needed. Integrated decision support systems in electronic patient records that remind nurses to inspect peripheral venous catheters regularly could be one solution.

摘要

目的

本研究旨在比较在儿科护理中电子病历中实施模板前后外周静脉导管记录的准确性和完整性。

背景

为了提高质量和进行研究,并确保患者安全,患者记录中需要有准确的临床数据。多项研究表明,所进行的护理与患者记录中的记录之间的关系很差。

设计

前后对照研究。

方法

该研究在瑞典的一家大型儿科大学医院进行。纳入标准为:入住纳入病房的患者、有一条或多条外周静脉导管、在数据收集时在病房内。在引入外周静脉导管记录模板之前和之后的四个月和十个月,通过观察和记录审核收集数据,该模板以结构化和标准化的方式记录外周静脉导管。

结果

与干预前相比,干预后外周静脉导管记录完整的数量显著增加。有记录的外周静脉导管的百分比相对稳定(85-93%)。外周静脉导管插入的总体记录没有改善,但干预后,侧位和尺寸的记录有所增加。在干预前观察到的 22 种并发症中有 1 种得到了记录,而在干预后没有记录到任何并发症(n=17 和 n=9)。

结论

电子病历既不能在干预前后提供儿科护理中外周静脉导管的准确数据。

临床意义

需要进一步努力提高与导管相关的并发症的记录。电子病历中集成的决策支持系统,可以定期提醒护士检查外周静脉导管,这可能是一种解决方案。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验