Suppr超能文献

尿中总雌激素的放射免疫测定法。

Radioimmunoassay of total urinary estrogens.

作者信息

Bordens R W, Engel R H

出版信息

Clin Chem. 1979 Jul;25(7):1323-4.

PMID:222505
Abstract

We describe a radioimmunoassay for total estrogens in urine. Estrogens are extracted by adsorption on XAD-2 resin, eluted with methanol, and acid-hydrolyzed. Estrogens are then determined in a diluted aliquot of the hydrolysate. Within-run coefficients of variation for estriol values between 6.0 and 100 micrograms/L were less than 5%; between-run CV was 19.6% at an estriol concentration of 16.8 microgram/L. A correlation coefficient of 0.96 was found on comparison of the radioimmunoassay (y) with a standard fluorometric assay (x); the regression equation is y = 2.18 x - 6.70 micrograms/L. Determination on pregnancy and non-pregnancy urine can be done within 4 h.

摘要

我们描述了一种用于检测尿液中总雌激素的放射免疫分析方法。雌激素通过吸附在XAD - 2树脂上进行提取,用甲醇洗脱,然后进行酸水解。接着在水解产物的稀释等分试样中测定雌激素。雌三醇值在6.0至100微克/升之间的批内变异系数小于5%;在雌三醇浓度为16.8微克/升时,批间变异系数为19.6%。将放射免疫分析(y)与标准荧光测定法(x)进行比较,发现相关系数为0.96;回归方程为y = 2.18x - 6.70微克/升。妊娠和非妊娠尿液的检测可在4小时内完成。