Department of Ophthalmology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
J Glaucoma. 2013 Sep;22(7):559-64. doi: 10.1097/IJG.0b013e31824484b9.
To compare the ability of time-domain optical coherence tomography (OCT) to detect diffuse and localized retinal nerve fiber layer (RNFL) defects using a built-in normative database in patients with early to moderate glaucoma.
Subjects with localized visual field defects confined to either hemifield were consecutively recruited. Only 1 eye per subject was considered. Among the 91 eyes with localized RNFL defects, 46 eyes with mean deviations matched to those of the 46 eyes with diffuse RNFL defects were selected for statistical analysis. This case-control study included 46 eyes with diffuse RNFL defects and 46 eyes with localized RNFL defects. The fast RNFL thickness protocol of Stratus OCT was used. The clock-hour and quadrant sector parameters corresponding to the hemifield with the visual field defect were evaluated at P<0.05 with regard to the built-in normative database. The sensitivities of these parameters were compared between diffuse and localized RNFL defects.
The sensitivity of the clock-hour sector parameter for diffuse RNFL defects (84.8%) was not significantly different than that for localized RNFL defects (80.4%) (P=0.78). The sensitivity of the quadrant sector parameter for diffuse RNFL defects (74.9%) was significantly higher than that for localized RNFL defects (52.3%) (P=0.04).
The clock-hour parameter of time-domain OCT detected RNFL defects without significant difference in sensitivities between diffuse and localized patterns of RNFL loss in glaucomatous eyes. However, the quadrant parameter of OCT showed better sensitivity for diffuse RNFL defects than for localized RNFL defects.
比较时域光学相干断层扫描(OCT)在使用内置正常数据库检测早期至中度青光眼患者弥漫性和局限性视网膜神经纤维层(RNFL)缺损的能力。
连续招募局限性视野缺损局限于半视野的患者。每个患者仅考虑 1 只眼。在 91 只具有局限性 RNFL 缺损的眼中,选择 46 只具有与弥漫性 RNFL 缺损相匹配的平均偏差的眼进行统计分析。这项病例对照研究包括 46 只弥漫性 RNFL 缺损眼和 46 只局限性 RNFL 缺损眼。使用 Stratus OCT 的快速 RNFL 厚度方案。在与视野缺损相对应的半视野,评估与内置正常数据库相对应的时钟小时和象限扇区参数(P<0.05)。比较弥漫性和局限性 RNFL 缺损之间这些参数的敏感性。
弥漫性 RNFL 缺损的时钟小时扇区参数的敏感性(84.8%)与局限性 RNFL 缺损的敏感性(80.4%)无显著差异(P=0.78)。弥漫性 RNFL 缺损的象限扇区参数的敏感性(74.9%)明显高于局限性 RNFL 缺损的敏感性(52.3%)(P=0.04)。
在青光眼眼中,时域 OCT 的时钟小时参数检测到的 RNFL 缺损的敏感性在弥漫性和局限性 RNFL 丧失模式之间没有显著差异。然而,OCT 的象限参数对弥漫性 RNFL 缺损的敏感性优于局限性 RNFL 缺损。