Suppr超能文献

表面后处理对纤维桩与根管表面黏结强度的影响。

The effect of post surface treatments on the bond strength of fiber posts to root surfaces.

机构信息

Faculty of Dentistry, Department of Prosthodondics, Mustafa Kemal University, 31 000, Hatay, Turkey.

出版信息

Lasers Med Sci. 2013 Jan;28(1):13-8. doi: 10.1007/s10103-012-1053-z. Epub 2012 Jan 25.

Abstract

The aim of the present study was to evaluate the influence of post surface treatment methods on the push-out bond strength of adhesively luted quartz fiber posts. Thirty freshly extracted and endodontically treated human incisor teeth were prepared for quartz fiber posts. The posts were submitted to three different surface treatments (n = 10), including no treatment, 50-µm aluminum-oxide (Al(2)O(3)) airborne-particle abrasion and Er:YAG laser (10 Hz, 150 mJ) irradiation. The posts were luted with resin cement. Each root was sectioned perpendicularly to its long axis to create specimens of 1-mm thickness. After the specimens were stored in distilled water at 37°C for 24 h, their push-out bond strength was tested using a universal testing machine at a crosshead speed of 1 mm/min. The data were analyzed by two-way ANOVA (α = .05). The two-way ANOVA indicated that push-out test values did not vary significantly according to surface treatments applied (control, airborne particle abrasion, Er:YAG laser irradiation) (p > 0.05), however, values varied according to the root segments (cervical, middle, and apical) (p < 0.01). The push-out bond strength values of the coronal root sections were the highest (p < 0.05) and there were no significant differences between the middle and apical root sections in push-out bond strength of fiber posts (p > 0.05). Air-borne particle abrasion or Er:YAG laser irradiation applied on the quartz fiber posts did not affect the push-out bond strengths relative to the root surfaces. The highest bond strength was observed in the cervical third of the roots in all groups.

摘要

本研究旨在评估表面后处理方法对黏结石英纤维桩推出强度的影响。将 30 颗新鲜拔出并经根管治疗的人切牙预备用于石英纤维桩。将纤维桩分别进行三种不同的表面处理(n = 10),包括不处理、50-µm 氧化铝(Al2O3)空气动力喷砂和 Er:YAG 激光(10 Hz,150 mJ)照射。然后用树脂水门汀黏结纤维桩。将每个牙根垂直于其长轴切成 1-mm 厚的试件。将试件在 37°C 的蒸馏水中储存 24 h 后,使用万能试验机以 1 mm/min 的十字头速度进行推出强度测试。数据采用双因素方差分析(α =.05)进行分析。双因素方差分析表明,根据应用的表面处理(对照组、空气动力喷砂、Er:YAG 激光照射),推出测试值没有显著差异(p > 0.05),然而,值根据根段(颈段、中段和根尖段)而变化(p < 0.01)。根尖段的推出黏结强度值最高(p < 0.05),并且在纤维桩的中段和根尖段的推出黏结强度之间没有显著差异(p > 0.05)。对石英纤维桩应用空气动力喷砂或 Er:YAG 激光照射不会影响相对于牙根表面的推出黏结强度。在所有组中,在根的颈段观察到最高的黏结强度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验