Suppr超能文献

Evaluation of a commercial radioimmunoassay kit for the detection of lysergide (LSD) in serum, whole blood, urine and stomach contents.

作者信息

Altunkaya D, Smith R N

机构信息

Metropolitan Police Forensic Science Laboratory, London, U.K.

出版信息

Forensic Sci Int. 1990 Sep;47(2):113-21. doi: 10.1016/0379-0738(90)90205-d.

Abstract

The Diagnostic Products Corporation Coat-A-Count radioimmunoassay kit for LSD in urine has been evaluated for use in forensic toxicology with a variety of sample types. The cut-offs (defined as the mean response of blank samples plus three standard deviation) for LSD in serum, haemolysed whole blood, urine and stomach contents were 0.06, 0.050-0.055, 0.18 and 0.18 ng/ml, respectively. Preliminary extraction of LSD from the samples is not usually necessary. The precision of the analysis and the recoveries from spiked samples were satisfactory. The cross-reactivities of 2-oxo-LSD, lysergic acid methyl propylamide, lysergic acid monoethylamide and nor-LSD were estimated to be 11,6,2 and 1% respectively relative to LSD (100%).

摘要

相似文献

5
8
Body fluid levels of lysergide (LSD).麦角酰二乙胺(LSD)的体液水平。
Forensic Sci Int. 1985 Aug;28(3-4):229-37. doi: 10.1016/0379-0738(85)90133-1.