Crosara Serena, Ljungvall Ingrid, Margiocco Marco L, Häggström Jens, Tarducci Alberto, Borgarelli Michele
Department of Animal Pathology, University of Torino, Grugliasco, Italy.
Am J Vet Res. 2012 Feb;73(2):194-201. doi: 10.2460/ajvr.73.2.194.
To evaluate reproducibility of ejection fraction (EF), myocardial perfusion (MP), and pulmonary transit time (PTT) measured in a group of dogs by use of contrast echocardiography and to examine safety of this method by evaluating cardiac troponin I concentrations.
6 healthy dogs.
2 bolus injections and a constant rate infusion of contrast agent were administered IV. Echocardiographic EF was determined by use of the area-length method and was calculated without and with contrast agent. The PTT and normalized PTT (PTT/mean R-R interval) were measured for each bolus. Constant rate infusion was used for global MP evaluation, and regional MP was calculated by use of a real-time method in 4 regions of interest of the left ventricle. Cardiac troponin I concentration was analyzed before and after contrast agent administration. Intraoberserver and interobserver variability was calculated.
EF was easier to determine with the ultrasonographic contrast agent. For the first and second bolus, mean ± SD PTT was 1.8 ± 0.2 seconds and 2.1 ± 0.3 seconds and normalized PTT was 3.4 ± 0.3 seconds and 3.5 ± 0.3 seconds, respectively. A coefficient of variation < 15% was obtained for global MP but not for the regional MPs. No differences were detected between precontrast and postcontrast cardiac troponin I concentrations.
Contrast echocardiography appeared to be a repeat-able and safe technique for use in the evaluation of global MP and PTT in healthy dogs, and it improved delineation of the endocardial border in dogs.
通过使用超声造影评估一组犬的射血分数(EF)、心肌灌注(MP)和肺循环时间(PTT)的可重复性,并通过评估心肌肌钙蛋白I浓度来检查该方法的安全性。
6只健康犬。
静脉内给予2次团注注射和1次造影剂恒速输注。使用面积-长度法测定超声心动图EF,并在使用造影剂和不使用造影剂的情况下进行计算。对每次团注测量PTT和标准化PTT(PTT/平均R-R间期)。使用恒速输注进行整体MP评估,并通过实时方法在左心室的4个感兴趣区域计算局部MP。在给予造影剂前后分析心肌肌钙蛋白I浓度。计算观察者内和观察者间的变异性。
使用超声造影剂更容易测定EF。对于第一次和第二次团注,平均±标准差PTT分别为1.8±0.2秒和2.1±0.3秒,标准化PTT分别为3.4±0.3秒和3.5±0.3秒。整体MP的变异系数<15%,但局部MP未达到。造影剂给药前后心肌肌钙蛋白I浓度未检测到差异。
超声造影似乎是一种可重复且安全的技术,可用于评估健康犬的整体MP和PTT,并且它改善了犬心内膜边界的描绘。