Raitt Merritt H, Kusumoto Walter
Portland VA Medical Center and Oregon Health and Sciences University, Portland, OR 97239, USA.
J Electrocardiol. 2012 May-Jun;45(3):296-303. doi: 10.1016/j.jelectrocard.2011.12.006. Epub 2012 Jan 26.
The frequency of surface atrial electrocardiogram (ECG) depolarization has been postulated to reflect the atrial effective refractory period (AERP).
Frequency analysis of surface ECGs after QRST subtraction and of electrograms from 4 right atrium and 4 coronary sinus electrode pairs was performed in 38 patients in atrial fibrillation. The AERP was measured in the right atrium and coronary sinus 10 minutes after cardioversion.
The correlation between the dominant frequencies of intracardiac electrograms and atrial activity in leads I, II, and V(1) were 0.89, 0.85, and 0.88, respectively (all P < .001). The correlation between the average AERP and the frequency of atrial activity in the surface leads was 0.50, 0.45, and 0.47 (all P < .005).
In atrial fibrillation, the frequency of atrial depolarization measured from the surface ECG is highly correlated with intracardiac atrial frequency. However, the correlation between the frequency of surface atrial activity and atrial refractoriness, although significant, is not strong.
体表心房心电图(ECG)去极化频率被假定可反映心房有效不应期(AERP)。
对38例房颤患者进行了QRST减法后体表ECG的频率分析以及来自4对右心房和4对冠状窦电极的电图分析。在复律后10分钟测量右心房和冠状窦的AERP。
心内电图的主导频率与I、II和V(1)导联心房活动之间的相关性分别为0.89、0.85和0.88(均P <.001)。平均AERP与体表导联心房活动频率之间的相关性为0.50、0.45和0.47(均P <.005)。
在房颤中,从体表ECG测量的心房去极化频率与心内心房频率高度相关。然而,体表心房活动频率与心房不应期之间的相关性虽显著,但并不强。