采用快速平面成像方案的新型心肌灌注剂替硼肟(SO 30,217)的诊断价值:初步结果

Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: preliminary results.

作者信息

Hendel R C, McSherry B, Karimeddini M, Leppo J A

机构信息

Department of Nuclear Medicine, University of Massachusettes Medical Center, Worcester.

出版信息

J Am Coll Cardiol. 1990 Nov;16(6):855-61. doi: 10.1016/s0735-1097(10)80333-x.

Abstract

Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxoime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed.

摘要

锝-99m标记的试剂在光子统计学、成本和临床可用性方面比铊-201具有优势。它们已被建议作为铊用于心肌灌注成像的替代物。替硼肟是一种新型的二肟锝硼酸加合物(BATO)化合物,在初步研究中显示出良好的特性。使用一种新颖的(坐位)患者定位技术和快速动态采集方案,30例患者在静息状态和最大运动平板运动后接受了替硼肟的平面成像。运动后扫描的平均完成时间(均值±标准差)为4.4±1.6分钟,静息状态下各视图的完成时间为4.8±1.5分钟。将这些结果与运动平板运动后的冠状动脉造影或铊闪烁扫描结果,或两者进行比较。30例患者中有28例存在诊断一致性(异常与正常)(p<0.001)。与铊闪烁扫描相比,在生理评估方面,分别有89%和86%的患者梗死和缺血的发现是一致的。本报告描述了替硼肟与快速动态平面成像技术的首次应用,结果显示与运动铊闪烁扫描具有高度相关性。运动后5至10分钟获得的运动后延迟图像显示,运动后初始(0至5分钟)视图中出现的运动诱发缺损迅速消失。替硼肟的快速差异洗脱此前尚未见报道,并对其可能的临床意义进行了讨论。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验