Suppr超能文献

使用 LeGoo 热可逆聚合物进行外周血管旁路无夹闭远端吻合的初步结果。

First results of clampless distal anastomosis in peripheral vascular bypass with LeGoo, a thermoreversible polymer.

机构信息

Service de chirurgie cardio vasculaire CHU Le Bocage, Dijon, France.

出版信息

J Vasc Surg. 2012 Jun;55(6):1821-5. doi: 10.1016/j.jvs.2011.11.103. Epub 2012 Feb 1.

Abstract

BACKGROUND

We report our initial experience with LeGoo (Pluromed Inc, Woburn, Mass), a temporary thermoreversible occlusive gel, in peripheral vascular revascularization.

METHODS

Between 2007 and 2010, LeGoo was used to occlude target vessels during bypass surgery in 14 patients who required infrainguinal revascularization.

RESULTS

Proximal occlusion of the target vessel was obtained with a mean quantity of 0.25 mL of LeGoo. Distal occlusion of the vessel was obtained with a mean quantity of 0.28 mL. One injection of LeGoo was sufficient to prevent backbleeding in 11 of 14 patients. The mean occlusion time was 13.4 ± 3.3 minutes. An injection of saline through the graft or better directly into the arteries was used to dissolve the gel. For our first case, a Fogarty catheter was used to remove residual gel from the anterior tibial artery.

CONCLUSIONS

LeGoo gel can be used to stop blood flow in small-bore arteries in the lower limbs to allow anastomoses to be performed.

摘要

背景

我们报告了 LeGoo(Pluromed Inc,马萨诸塞州沃本市)在周围血管血运重建中的初步应用经验,LeGoo 是一种临时热可逆闭塞凝胶。

方法

在 2007 年至 2010 年间,14 名需要下肢血运重建的患者在旁路手术中使用 LeGoo 闭塞目标血管。

结果

用 LeGoo 平均 0.25 mL 获得目标血管的近端闭塞,平均 0.28 mL 获得血管的远端闭塞。14 名患者中有 11 名患者,1 次注射 LeGoo 即可防止逆行出血。平均闭塞时间为 13.4 ± 3.3 分钟。通过移植物或更好地直接向动脉内注射盐水来溶解凝胶。对于我们的首例病例,使用 Fogarty 导管从胫前动脉清除残留的凝胶。

结论

LeGoo 凝胶可用于阻止下肢小口径动脉的血流,以进行吻合术。

相似文献

1
First results of clampless distal anastomosis in peripheral vascular bypass with LeGoo, a thermoreversible polymer.
J Vasc Surg. 2012 Jun;55(6):1821-5. doi: 10.1016/j.jvs.2011.11.103. Epub 2012 Feb 1.
4
The world of LeGoo assessed: a short systematic and critical review.
Eur J Vasc Endovasc Surg. 2013 Jan;45(1):44-5. doi: 10.1016/j.ejvs.2012.10.021. Epub 2012 Nov 13.
5
Investigations of a thermosensitive gel to temporarily occlude crural arteries in femoro-distal bypass surgery.
Eur J Vasc Endovasc Surg. 2013 Jan;45(1):46-50. doi: 10.1016/j.ejvs.2012.10.005. Epub 2012 Nov 3.
6
Clinical experience with a novel thermosensitive temporary coronary artery occluder (LeGoo).
Ann Thorac Surg. 2010 Jun;89(6):1912-7. doi: 10.1016/j.athoracsur.2010.03.015.
7
Blood transfusion is associated with increased morbidity and mortality after lower extremity revascularization.
J Vasc Surg. 2010 Mar;51(3):616-21, 621.e1-3. doi: 10.1016/j.jvs.2009.10.045. Epub 2010 Jan 27.
8
Effects of the novel polymer gel LeGoo on human internal thoracic arteries.
Ann Thorac Surg. 2011 Dec;92(6):2235-9. doi: 10.1016/j.athoracsur.2011.05.012.
9
Evaluation of a novel reverse thermosensitive polymer for use in microvascular surgery.
J Reconstr Microsurg. 2009 Jan;25(1):69-76. doi: 10.1055/s-0028-1104556. Epub 2008 Dec 9.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验