Suppr超能文献

8毫米和9毫米甲基丙烯酸羟乙酯盘状人工晶状体的早期结果。

Early results with the 8 mm and 9 mm HEMA disc intraocular lens.

作者信息

Budo C J, Montanus F F, Poulicek M J

出版信息

J Cataract Refract Surg. 1990 Sep;16(5):578-82. doi: 10.1016/s0886-3350(13)80772-9.

Abstract

This study presents our experience with 34 HEMA disc intraocular lenses implanted in the capsular bag. Despite the small number of cases and the relatively short mean postoperative follow-up of nine months, the results show a low incidence of uveitis and capsular fibrosis and excellent biocompatibility. The following complications were observed: four luxations of the 8 mm lens and one of the 9 mm lens in the anterior chamber. A visual acuity of 20/20 to 20/40 was obtained in 32 patients (94%).

摘要

本研究介绍了我们在34例将HEMA盘状人工晶状体植入囊袋中的经验。尽管病例数较少,术后平均随访时间相对较短,仅9个月,但结果显示葡萄膜炎和囊膜纤维化的发生率较低,且生物相容性良好。观察到以下并发症:8毫米晶状体有4例脱位至前房,9毫米晶状体有1例脱位至前房。32例患者(94%)的视力达到了20/20至20/40。