Suppr超能文献

Feline plasma cortisol (hydrocortisone) measured by radioimmunoassay.

作者信息

Johnston S D, Mather E C

出版信息

Am J Vet Res. 1979 Feb;40(2):190-2.

PMID:223475
Abstract

Plasma cortisol (hydrocortisone) was measured by radioimmunoassay in 6 normal cats. Blood was collected from the cats by venipuncture at intervals of 3 hours for 3 days. Resting plasma cortisol concentrations averaged 17.0 +/- 2.8 (SD) ng/ml and ranged from nondetectable (less than 3 ng/ml) to 82.8 ng/ml. Of 144 plasma samples, 95% contained less than 40 ng of cortisol/ml. Circadian rhythm of cortisol secretion was not detected, suggesting that adrenal function tests may be started in feline patients at any time of day. Intramuscular injection of 2.2 U of ACTH gel/kg of body weight caused detectable increase in plasma cortisol concentrations at 1 and 2 hours after injection. Maximal response to ACTH in the 6 cats ranged from 41.6 to 178.4 ng/ml. Oral administration of 0.1 mg of dexamethasone/kg suppressed plasma cortisol to nondetectable concentrations for 32 hours in 5 of the 6 cats.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验