Patil Sachin Ramrao, Kumar Lokesh, Kohli Gunjan, Bansal Arvind Kumar
Department of Pharmaceutical Technology (Formulations), National Institute of Pharmaceutical Education and Research (NIPER), S.A.S. Nagar, Mohali, Punjab-160 062, India.
Sci Pharm. 2012 Jan-Mar;80(1):89-100. doi: 10.3797/scipharm.1109-03. Epub 2011 Oct 22.
The present work explains the development and validation of a simple, rapid and sensitive liquid chromatographic method for the simultaneous determination of antipyrine (ANT), carbamazepine (CBZ), furosemide (FSD) and phenytoin (PHTN). Chromatographic analysis was carried out by a reversed phase technique on a C18 column, using water pH 3.0 and 50:50 mixtures of methanol and acetonitrile (58:42 v/v) as the mobile phase, at a flow-rate of 1.0 ml/min and a column temperature of 40°C. Detection was carried out at 205 nm for CBZ and PHTN and at 230 nm for ANT and FSD. The proposed method was evaluated for validation parameters including linearity, range, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ) and specificity. Elution of drugs ANT, FSD, PHTN, and CBZ was observed at 4.1, 5.1, 12.3 and 13.5 min, respectively. The method was found to be linear (R(2) ≥ 0.999) in the concentration range of 5-100 μM, with an acceptable accuracy and relative standard deviation. Results of intra- and inter-day validation (n=3) showed the method to be efficient for routine determination of these permeability markers in Caco-2 cell monolayer permeability studies. The method was successfully utilized for determination of standard compounds in Caco-2 permeability experiments.
本研究阐述了一种用于同时测定安替比林(ANT)、卡马西平(CBZ)、呋塞米(FSD)和苯妥英(PHTN)的简单、快速且灵敏的液相色谱方法的开发与验证。采用反相技术在C18柱上进行色谱分析,以pH 3.0的水与甲醇和乙腈的50:50混合物(58:42 v/v)作为流动相,流速为1.0 ml/min,柱温为40°C。对CBZ和PHTN在205 nm处进行检测,对ANT和FSD在230 nm处进行检测。对所提出的方法进行了验证参数评估,包括线性、范围、准确度、精密度、检测限(LOD)、定量限(LOQ)和特异性。观察到药物ANT、FSD、PHTN和CBZ的洗脱时间分别为4.1、5.1、12.3和13.5分钟。该方法在5 - 100 μM的浓度范围内呈线性(R(2)≥0.999),具有可接受的准确度和相对标准偏差。日内和日间验证结果(n = 3)表明该方法在Caco - 2细胞单层通透性研究中对这些通透性标志物的常规测定有效。该方法已成功用于Caco - 2通透性实验中标准化合物的测定。