A new quality and quantity analyzing method for waste gas from chemical industry, especially for acrylic acid ester using air-sampling combined with GC/MS and honeywell air purifier system was firstly advanced in this paper. According to the experiments, the maximum disposal capability of the honeywell air purifier system for acrylic acid ester gas was calculated as about 1 kg x h(-1) and the feasibility and validity of the method was also proved by parallel tests.
本文首次提出了一种新的化工废气质量和数量分析方法,特别是针对采用空气采样结合气相色谱/质谱联用以及霍尼韦尔空气净化系统的丙烯酸酯废气分析方法。通过实验计算得出,霍尼韦尔空气净化系统对丙烯酸酯气体的最大处理能力约为1 kg·h⁻¹,并且平行试验也证明了该方法的可行性和有效性。