Suppr超能文献

[鼻中隔矫正术后发生中毒性休克综合征的一例患者]

[A patient with toxic shock syndrome following correction of the nasal septum].

作者信息

Schweitzer D H, Moffie B G, van der Mey A G, Thompson J

机构信息

Afd. Infectieziekten, Academisch Ziekenhuis, Leiden.

出版信息

Ned Tijdschr Geneeskd. 1990 Nov 3;134(44):2146-8.

PMID:2247173
Abstract

A male aged 30 suffered from toxic shock syndrome after septorhinoplasty with positioning of a tampon. Initial treatment consisted of removing the tampon and supportive care, as a result of which the patient recovered. The patient was a carrier of Staphylococcus aureus which produced toxic shock syndrome toxin-I (TSST-I). Anti-TSST-I antibodies were already found in the serum in the initial phase of the disease.

摘要

一名30岁男性在鼻中隔成形术并放置棉塞后患上中毒性休克综合征。初始治疗包括取出棉塞和支持性护理,患者因此康复。该患者是产中毒性休克综合征毒素-I(TSST-I)的金黄色葡萄球菌携带者。在疾病初期血清中就已发现抗TSST-I抗体。