Lee Juliana Tsz Yan, Chow King Lau
Bioengineering Graduate Program, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
Scanning. 2012 Jan-Feb;34(1):12-25. doi: 10.1002/sca.20271. Epub 2011 Aug 24.
Common dehydration methods of cells on biomaterials for scanning electron microscopy (SEM) include air drying, hexamethyldisilazane (HMDS) or tetramethysilane (TMS) treatment and critical point drying (CPD). On the other side, freeze-drying has been widely employed in dehydrating biological samples and also in preparing porous biomaterial scaffolds but not in preparing cells on three-dimensional (3D) biomaterials for SEM examination. In this study, we compare cells on porous hydroxyapatite (HA) prepared by air drying, HMDS and freeze-drying. The effects of fixation and using phosphate buffered saline (PBS) in the fixation were also assessed on three porous calcium phosphate (CaP) materials, namely, HA, α-tricalcium phosphate (α-TCP) and β-tricalcium phosphate (β-TCP) samples. There is no significant difference in samples prepared by HMDS treatment and freeze-drying viewed at low magnification. Besides, it is better not to use phosphate buffer in the fixation step for CaP materials to avoid undesirable spontaneous precipitation of CaPs. On the other hand, fewer exchanges of liquids are required for freeze-drying and hence chemical fixation may not be absolutely required for samples prepared by freeze-drying. Other technical details of the preparation were also investigated and discussed. This study suggests both HMDS and freeze-drying can be employed to dehydrate cells on 3D scaffolds for SEM examination.
用于扫描电子显微镜(SEM)的生物材料上细胞的常见脱水方法包括空气干燥、六甲基二硅氮烷(HMDS)或四甲基硅烷(TMS)处理以及临界点干燥(CPD)。另一方面,冷冻干燥已广泛应用于生物样品的脱水以及多孔生物材料支架的制备,但尚未用于制备用于SEM检查的三维(3D)生物材料上的细胞。在本研究中,我们比较了通过空气干燥、HMDS和冷冻干燥制备的多孔羟基磷灰石(HA)上的细胞。还评估了固定以及在固定中使用磷酸盐缓冲盐水(PBS)对三种多孔磷酸钙(CaP)材料(即HA、α-磷酸三钙(α-TCP)和β-磷酸三钙(β-TCP)样品)的影响。在低倍放大观察时,经HMDS处理和冷冻干燥制备的样品没有显著差异。此外,对于CaP材料,在固定步骤中最好不要使用磷酸盐缓冲液,以避免CaPs出现不良的自发沉淀。另一方面,冷冻干燥所需的液体交换较少,因此对于通过冷冻干燥制备的样品,可能不一定需要化学固定。还对制备的其他技术细节进行了研究和讨论。本研究表明,HMDS和冷冻干燥均可用于对3D支架上的细胞进行脱水以用于SEM检查。