Suppr超能文献

定义头颈部癌转移淋巴结肿瘤勾画的 PET 标准摄取值阈值。

Defining PET standardized uptake value threshold for tumor delineation with metastatic lymph nodes in head and neck cancer.

机构信息

Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Disease, 1-3-3 Nakamichi, Higashinari-ku, Osaka City, Osaka Prefecture, Japan.

出版信息

Jpn J Clin Oncol. 2012 Jun;42(6):491-7. doi: 10.1093/jjco/hys049. Epub 2012 Apr 29.

Abstract

OBJECTIVE

Hot spots of F-18 fluorodeoxyglucose positron emission tomograms are variable in size according to window settings of standardized uptake values. The purpose of this study was to determine the standardized uptake value threshold that represents the target volume.

METHODS

Sixty-three patients who underwent fluorodeoxyglucose positron emission tomographic computed tomography and were diagnosed as having head and neck cancer with cervical lymphadenopathy were studied. The horizontal and vertical diameters of metastatic lymph nodes (LN-CT) were measured at the center of computed tomographic images. Of the corresponding nodes, the maximal standardized uptake value (SUVmax) and standardized uptake value profiles along the central horizontal and vertical axes were calculated on positron emission tomographic images (LN-PET). On the standardized uptake value profiles, the standardized uptake value levels (SUVeq) where the size of LN-PET was equivalent to the diameters of LN-CT were obtained. The regression formula between SUVeq and SUVmax was obtained. The regression formula of SUVeq was validated in subsequent 30 positron emission tomographic computed tomography studies.

RESULTS

The mean horizontal and vertical diameters of LN-CT were 14.9 and 16.4 mm, respectively. SUVmax ranged from 1.88 to 9.07, and SUVeq was between 1.16 and 6.42. The regression formula between SUVeq and SUVmax was as follows: SUVeq = 1.21 + 0.34 × SUVmax (coefficient of correlation: R = 0.69). The validation study resulted in a good correlation between the volume of lymph nodes on computed tomography and positron emission tomographic computed tomography (R(2) = 0.93).

CONCLUSIONS

The formula with a relatively high coefficient of correlation is considered to indicate that SUVeq is not constant, but is a complex of an absolute standardized uptake value and is proportional to SUVmax.

摘要

目的

氟-18 脱氧葡萄糖正电子发射断层扫描的热点大小根据标准化摄取值的窗口设置而变化。本研究的目的是确定代表靶体积的标准化摄取值阈值。

方法

对 63 例经氟脱氧葡萄糖正电子发射断层扫描计算机断层扫描(PET/CT)检查并诊断为头颈部癌症伴颈部淋巴结转移的患者进行研究。在 CT 图像的中心测量转移性淋巴结(LN-CT)的水平和垂直直径。对于相应的淋巴结,在正电子发射断层扫描图像(LN-PET)上计算最大标准化摄取值(SUVmax)和沿中央水平和垂直轴的标准化摄取值分布。在标准化摄取值分布上,获得 LN-PET 大小与 LN-CT 直径相等的标准化摄取值水平(SUVeq)。获得 SUVeq 与 SUVmax 之间的回归公式。随后在 30 例 PET/CT 研究中验证了 SUVeq 的回归公式。

结果

LN-CT 的平均水平和垂直直径分别为 14.9mm 和 16.4mm。SUVmax 范围为 1.88 至 9.07,SUVeq 为 1.16 至 6.42。SUVeq 与 SUVmax 之间的回归公式如下:SUVeq = 1.21 + 0.34 × SUVmax(相关系数:R = 0.69)。验证研究结果表明 CT 上淋巴结的体积与 PET/CT 之间具有良好的相关性(R² = 0.93)。

结论

考虑到该公式具有较高的相关系数,SUVeq 不是恒定的,而是一个绝对标准化摄取值的综合体,与 SUVmax 成正比。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验