Suppr超能文献

使用Advance Medial Pivot假体进行全膝关节置换术的临床和影像学结果。平均随访7年。

Clinical and radiologic outcomes of total knee arthroplasty using the Advance Medial Pivot prosthesis. A mean 7 years follow-up.

作者信息

Vecchini E, Christodoulidis A, Magnan B, Ricci M, Regis D, Bartolozzi P

机构信息

Department of Orthopaedics and Traumatology, University of Verona, GB Rossi Hospital, Verona, Italy.

出版信息

Knee. 2012 Dec;19(6):851-5. doi: 10.1016/j.knee.2012.04.002. Epub 2012 May 7.

Abstract

BACKGROUND

Medial Pivot total knee prosthesis has been designed according to studies on normal knee kinematics aiming to replicate physiological knee movement. The purpose of this study was to evaluate clinical and radiologic results of the Advance Medial Pivot Total Knee Arthroplasty, at a mean follow-up of seven years.

METHODS

One hundred seventy two Medial Pivot total knee arthroplasties in 160 consecutive patients have been evaluated using the American Knee Society Score and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Statistical analysis was performed using the Student's t-test and the Wilcoxon matched-pairs signed-rank (Mann-Whitney) test in order to evaluate the significance of differences within the groups of patients. Patients compliance was 93.75% thus only six patients (3.75%) lost to follow-up and four patients (2.5%) died for reasons unrelated to the surgery.

RESULTS

The mean Knee Society score and range of motion was improved from 77.6 points and 97.7° to 152.8 points and 112.5° respectively (p<.001). In total 85.8% and 82.4% of the knees had an excellent (≥ 80) or good (70-79) functional and knee scores respectively. Relief of pain was satisfactory in 88.9% of the patients, while 96% of the patients return to age-related daily life activities. Stability and comfort during walking was subjectively judged by the patients as satisfactory in about 90%. Anterior knee pain was observed in eight patients (5.4%). The Kaplan-Meier survivorship analysis showed a cumulative success rate of 98.6%.

CONCLUSIONS

The results are encouraging but longer follow-up of this cohort is necessary in the study of this specific design. Level of evidence IV.

摘要

背景

内侧旋转全膝关节假体是根据对正常膝关节运动学的研究设计的,旨在复制生理性膝关节运动。本研究的目的是在平均七年的随访期内,评估进阶内侧旋转全膝关节置换术的临床和放射学结果。

方法

对160例连续患者的172例内侧旋转全膝关节置换术进行了评估,采用美国膝关节协会评分以及膝关节协会全膝关节置换术X线评估和评分系统。使用学生t检验和威尔科克森配对符号秩(曼-惠特尼)检验进行统计分析,以评估患者组内差异的显著性。患者依从率为93.75%,因此只有6例患者(3.75%)失访,4例患者(2.5%)因与手术无关的原因死亡。

结果

膝关节协会平均评分和活动范围分别从77.6分和97.7°提高到152.8分和112.5°(p<0.001)。总体而言,分别有85.8%和82.4%的膝关节功能评分和膝关节评分优秀(≥80)或良好(70-79)。88.9%的患者疼痛缓解令人满意,而96%的患者恢复了与年龄相关的日常生活活动。患者主观判断步行时的稳定性和舒适度约90%令人满意。8例患者(5.4%)出现膝前疼痛。Kaplan-Meier生存分析显示累积成功率为98.6%。

结论

结果令人鼓舞,但对于这种特定设计的研究,有必要对该队列进行更长时间的随访。证据等级IV。