Does using the medial or lateral humeral line improve reliability of Baumann angle measurement on plain x-ray? The effect of humeral length visualized on the x-ray.

作者信息

Krengel Walter F, Wiater Brett P, Pace James Lee, Jinguji Thomas M, Bompadre Viviana, Stults Janna K, Schmale Gregory A

机构信息

Department of Orthopedics and Sports Medicine, Seattle Children's and University of Washington, WA 98145-5005, USA.

出版信息

J Pediatr Orthop. 2012 Jun;32(4):373-7. doi: 10.1097/BPO.0b013e318251969f.

Abstract

BACKGROUND

Baumann angle (BA) is a common measure of coronal plane alignment of the distal humerus. We hypothesize that the reliability of measuring BA would be improved by using the medial and lateral cortical margins of the humerus seen on plain x-ray, rather than the estimated central humeral line, which is the "standard" technique. Further, we analyze whether the amount of humerus visible on the film improves the reliability of the method.

METHODS

A total of 71 anteroposterior elbow digital radiographs from patients aged 0 to 12 were measured 3 times by 5 qualified observers. Each digital measurement included (1) BA using the estimated central humeral line; (2) BA using the medial humeral line (BA-MHL); and (3) BA using the lateral humeral line (BA-LHL). Inadequate radiographs or those showing any indication of current or previous fracture were excluded. Intraobserver reliability was estimated for each rater using a 1-way analysis of variance model and interobserver reliability of each set of measurements was estimated using a 2-way analysis of variance.

RESULTS

The mean and SD for the BA, BA-MHL, and BA-LHL in females were 70.0 (6.73), 68.0 (6.84), and 72.3 (7.93), respectively, and for males 73.0 (5.22), 70.0 (5.56), and 76.0 (6.18), respectively. Intraobserver reliability (intraclass correlation coefficient) for BA, BA-MHL, and BA-LHL averaged 0.85, 0.92, and 0.90, respectively. Average interobserver reliability (intraclass correlation coefficient) for BA, BA-MHL, and BA-LHL were 0.79, 0.71, and 0.76, respectively. Intraobserver and interobserver reliability of BA and BA-LHL were significantly improved when at least 7 cm of humerus was visible on the x-ray, as compared with <7 cm visible.

CONCLUSIONS

Intrarater reliability is better for both BA-LHL and BA-MHL than for standard BA (using the estimated central humeral axis). Interrater reliability was best using standard BA. Reliability of all methods is improved when >7 cm of the distal humerus is visible on the radiograph. In addition, at least 7 cm of the distal humerus on anteroposterior radiographs improves reliability of measuring BA.

LEVEL OF EVIDENCE

Diagnostic study-Level II.

摘要

背景

鲍曼角(BA)是评估肱骨远端冠状面排列的常用指标。我们推测,通过使用普通X线片上可见的肱骨内侧和外侧皮质边缘来测量BA,而非采用“标准”技术中估计的肱骨干中心线,测量的可靠性会得到提高。此外,我们分析了X线片上可见的肱骨长度是否会提高该方法的可靠性。

方法

5名合格观察者对71例0至12岁患者的肘关节前后位数字X线片各测量3次。每次数字测量包括:(1)使用估计的肱骨干中心线测量BA;(2)使用肱骨内侧线测量BA(BA-MHL);(3)使用肱骨外侧线测量BA(BA-LHL)。排除X线片显示不清晰或有当前或既往骨折迹象的病例。使用单因素方差分析模型评估每位观察者的测量结果的观察者内可靠性,使用双因素方差分析评估每组测量结果的观察者间可靠性。

结果

女性的BA、BA-MHL和BA-LHL的均值及标准差分别为70.0(6.73)、68.0(6.84)和72.3(7.93),男性分别为73.0(5.22)、70.0(5.56)和76.0(6.18)。BA、BA-MHL和BA-LHL的观察者内可靠性(组内相关系数)平均分别为0.85、0.92和0.90。BA、BA-MHL和BA-LHL的观察者间可靠性(组内相关系数)平均分别为0.79、0.71和0.76。与X线片上可见肱骨长度<7 cm相比,当X线片上可见至少7 cm的肱骨时,BA和BA-LHL的观察者内及观察者间可靠性均显著提高。

结论

BA-LHL和BA-MHL的观察者内可靠性均优于标准BA(使用估计的肱骨干中轴线)。使用标准BA时观察者间可靠性最佳。当X线片上可见>7 cm的肱骨远端时,所有测量方法的可靠性均提高。此外,肘关节前后位X线片上至少有7 cm的肱骨远端可提高BA测量的可靠性。

证据水平

诊断性研究-二级。