Cornea Research Chair, Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
Microsc Res Tech. 2012 Oct;75(10):1420-4. doi: 10.1002/jemt.22083. Epub 2012 May 31.
The corneal tissue was processed in fixatives and embedded in resin for transmission electron microscopy to observe the ultrastructure of the collagen fibrils (CFs). The effect of these processing methods on the CF diameter and the interfibrillar spacing was studied.
Four normal human corneal buttons were used for this study. A part of each cornea was fixed in 2.5% glutaraldehyde containing cuprolinic blue in sodium acetate buffer and embedded in spurr's resin (SpurrCB). A second part of each cornea was fixed in 2.5% glutaraldehyde + osmium tetroxide and embedded spurr's resin (SpurrOsm). The third part of each cornea was fixed in paraformaldehyde (4%) and embedded in LR White at 4°C (LRWhite). Ultrathin sections were stained with uranyl acetate and lead citrate.
In the tissue, fixed in SpurrCB, the diameter was 38.4 ± 5.9 nm and spacing between CF was 52.5 ± 5.3 nm. In the tissue fixed in SpurrOsm, the diameter was 28.37 ± 5.84 nm and spacing between CF was 45 ± 4.57 nm. In the tissue fixed in LR White, the CF diameter was 24 ± 2.3 nm and spacing between CF was 39.0 ± 4.2 nm. The diameters and interfibrillar spacing of the tissue processed by SpurrCB, SpurrOsm, and LRWhite were significantly different (P < 0.001) from one another.
Our study shows that there is a variation in the CF diameter and spacing depending on the method of fixation and embedding resins used. This needs to be considered when comparative studies using different methods are done.
本研究将角膜组织用固定剂固定并包埋在树脂中,通过透射电子显微镜观察胶原纤维(CF)的超微结构。本研究旨在研究这些处理方法对 CF 直径和纤维间间距的影响。
本研究使用了 4 个人类正常眼角膜。每只眼角膜的一部分用含有铜蓝的 2.5%戊二醛固定,然后嵌入 Spurr 树脂(SpurrCB)中。每只眼角膜的另一部分用 2.5%戊二醛+锇酸固定,然后嵌入 Spurr 树脂(SpurrOsm)中。每只眼角膜的第三部分用多聚甲醛(4%)固定并在 4°C 下嵌入 LR White(LRWhite)中。超薄切片用醋酸铀和柠檬酸铅染色。
在 SpurrCB 固定的组织中,CF 直径为 38.4 ± 5.9nm,纤维间间距为 52.5 ± 5.3nm。在 SpurrOsm 固定的组织中,CF 直径为 28.37 ± 5.84nm,纤维间间距为 45 ± 4.57nm。在 LRWhite 固定的组织中,CF 直径为 24 ± 2.3nm,纤维间间距为 39.0 ± 4.2nm。用 SpurrCB、SpurrOsm 和 LRWhite 处理的组织的 CF 直径和纤维间间距差异有统计学意义(P<0.001)。
本研究表明,CF 直径和间距因固定和包埋树脂的方法而异。在使用不同方法进行比较研究时,需要考虑这一点。