有效标记放置用于髋关节旋转中心的功能识别。

Effective marker placement for functional identification of the centre of rotation at the hip.

机构信息

Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Center for Sports Science and Sports Medicine Berlin, Philippstr. 13, Haus 11, 10115 Berlin, Germany.

出版信息

Gait Posture. 2012 Jul;36(3):482-6. doi: 10.1016/j.gaitpost.2012.04.011. Epub 2012 Jun 5.

Abstract

The accuracy and precision of quantifying musculoskeletal kinematics, and particularly determining the centre of rotation (CoR) at the hip joint, using skin marker based motion analysis is limited by soft tissue artefact (STA). We posed the question of whether the contribution of individual markers towards improving the precision of the functional joint centre using marker based methods could be assessed, and then utilised to allow effective marker placement for determination of the CoR at the hip. Sixty-three retro-reflective skin markers were placed to encompass the thighs of seven healthy subjects, together with a set of sixteen markers on the pelvis. The weighted optimal common shape technique (wOCST) was then applied to determine the weighting, or importance, of each marker for identifying the centre of rotation at the hip. The markers with the highest weightings over all subjects and measurements were determined that identified the HJC with the highest precision. The use of six markers in selected regions (two anterior, two lateral and two posterior) allowed the HJC to be determined with a similar precision to the complete set of 63 markers, with the determined regions predominantly distant from the hip joint, excluding areas associated with the bellies of large muscles and therefore large motion artefact from muscle activity. The novel approach presented here allows an understanding of each marker's contribution towards a precise joint determination, and therefore enables the targeted placement of markers for reliable assessment of musculoskeletal kinematics.

摘要

基于皮肤标记的运动分析技术在定量测量肌肉骨骼运动学,尤其是确定髋关节的旋转中心(CoR)时,其准确性和精密度受到软组织运动伪影(STA)的限制。我们提出了这样一个问题,即是否可以评估基于标记的方法中单个标记对提高功能关节中心精度的贡献,然后利用这些标记来确定髋关节的 CoR 以实现有效的标记放置。将 63 个反光皮肤标记放置在 7 位健康受试者的大腿周围,同时在骨盆上放置一组 16 个标记。然后应用加权最优公共形状技术(wOCST)来确定每个标记对于识别髋关节旋转中心的权重或重要性。确定所有受试者和测量中具有最高权重的标记,这些标记能够以最高精度确定 HJC。在选定区域(两个前侧、两个外侧和两个后侧)使用六个标记可以以类似于使用 63 个标记的完整集合的精度确定 HJC,所确定的区域主要远离髋关节,排除了与大肌肉腹部相关的区域,从而减少了来自肌肉活动的大运动伪影。这里提出的新方法可以了解每个标记对精确关节确定的贡献,从而能够针对可靠的肌肉骨骼运动学评估进行有针对性的标记放置。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验