Weiland M, Werner H
Sektion Stomatologie der Medizinischen Akademie Carl Gustav Carus, Dresden.
Stomatol DDR. 1990 Jun;40(6):270-2.
In a cell with artificial saliva the electrochemical behaviour of amalgam specimens of Germadent, Duragam and ANA 2000 are characterized in dependence of different mechanical treatments of surfaces using cycling voltimetry. In the beginning the influence of roughness on the corrosion is evident, but increasing the influence of chemical composition dominant. Duragam-amalgam is most resistant to corrosion. The content of copper in Duragam has a better effect than the high content of copper in ANA 2000.