Suppr超能文献

洗必泰-磺胺嘧啶银浸渍中心静脉导管:体外抗菌活性及对细菌黏附的影响

Chlorhexidine-silver sulfadiazine-impregnated central venous catheters: in vitro antibacterial activity and impact on bacterial adhesion.

作者信息

Monzillo Vincenzina, Corona Silvia, Lanzarini Paolo, Dalla Valle Claudia, Marone Piero

机构信息

Dipartimento di Malattie Infettive, Universita egli Studi di Pavia, Italy.

出版信息

New Microbiol. 2012 Apr;35(2):175-82. Epub 2012 Mar 31.

Abstract

The aim of this study was to compare the in vitro activity and the impact on bacterial adhesion of two different catheters, one impregnated with chlorhexidine-silver sulfadiazine (C-SS) and the other not impregnated with antibacterial agents. The antimicrobial coating prevented the bacterial colonization by slime positive Staphylococcus epidermidis in the first two days. The antibacterial activity of the effluents from catheters impregnated with C-SS dissipated by day seven. Our results demonstrated that the surface treatment modified the composition of impregnated catheters and determined different contact angle values of the two catheters (impregnated and not impregnated). Examination of coated and uncoated catheter segments by scanning electron microscopy showed a good correlation with the results of adherence experiments. In conclusion, the findings suggest that C-SS coated catheters prevent in vitro bacterial adhesion.

摘要

本研究的目的是比较两种不同导管的体外活性及其对细菌黏附的影响,一种导管浸渍有氯己定-磺胺嘧啶银(C-SS),另一种未浸渍抗菌剂。抗菌涂层在前两天阻止了黏液阳性表皮葡萄球菌的细菌定植。浸渍有C-SS的导管流出物的抗菌活性在第7天时消失。我们的结果表明,表面处理改变了浸渍导管的组成,并确定了两种导管(浸渍和未浸渍)不同的接触角值。通过扫描电子显微镜检查涂覆和未涂覆的导管段,结果与黏附实验结果具有良好的相关性。总之,研究结果表明,C-SS涂覆的导管可防止体外细菌黏附。

相似文献

2
In vitro evaluation of the antibacterial activity of three different central venous catheters against gram-positive bacteria.
Eur J Clin Microbiol Infect Dis. 2002 May;21(5):379-84. doi: 10.1007/s10096-002-0719-z. Epub 2002 May 14.
5
Comparative in vitro efficacies and antimicrobial durabilities of novel antimicrobial central venous catheters.
Antimicrob Agents Chemother. 2006 Oct;50(10):3283-8. doi: 10.1128/AAC.01622-05.
6
A comparison of two antimicrobial-impregnated central venous catheters. Catheter Study Group.
N Engl J Med. 1999 Jan 7;340(1):1-8. doi: 10.1056/NEJM199901073400101.
7
Activity of antibacterial impregnated central venous catheters against Klebsiella pneumoniae.
Intensive Care Med. 2002 Apr;28(4):438-42. doi: 10.1007/s00134-002-1243-4. Epub 2002 Mar 15.

引用本文的文献

2
SiO nanosphere coated tough catheter with superhydrophobic surface for improving the antibacteria and hemocompatibility.
Front Bioeng Biotechnol. 2023 Jan 10;10:1067139. doi: 10.3389/fbioe.2022.1067139. eCollection 2022.
3
In vitro efficacy of a novel active-release antimicrobial coating to eradicate biofilms of Pseudomonas aeruginosa.
Antimicrob Agents Chemother. 2014;58(4):2400-4. doi: 10.1128/AAC.01798-13. Epub 2014 Jan 6.