Cherkavskaia O V, Savchenko A P, Rudenko B A, Merkulov E V
Vestn Rentgenol Radiol. 2012 Mar-Apr(2):14-9.
To study the results after stenting extensive stenoses, the incidence of restenosis according to angiographic findings, as well as changes in endothelization and other morphological parameters in accordance with the data of intravascular ultrasound study (IVUSS).
The study included 220 coronary heart disease patients with extensive stenoses of the coronary bed. Double antiaggregant therapy was used in 90% of the patients during the first year and in 9.5% during the second year. Contrast-enhanced coronarography was performed in 174 and 82 patients within the first and second years following stent implantation, respectively. IVUSS was made in 26 patents by the end of the first year and in 24 patients by the end of the second year of a followup. Quantitative and qualitative analyses were done in terms of the following indicators: the mean minimal diameter of a stented segment; its mean minimal area; the number of stents with complete endothelization. RESULTS; In the first year, 1 (0.5%) patient had a fatal outcome; the development of Q-wave and non-Q-wave myocardial infarction (MI) was observed in 2 (1%) and 3 (1.5%) patients, respectively. The appearance of angina symptoms during a year was noted in 10 (4.5%) patients; coronary artery bypass grafting (CABG) was performed in 7 (3.2%) patients; 3 (1.5%) cases had endovascular reintervention. At 2-year follow-up, 6 (2.7%) patients died; 7 (3.2%) and 7 (3.2%) patients developed Q-wave and non-Q-wave MI, respectively; recurrent angina pectoris was noted in 22 (10%) patients. CABG was made in 5 (2.3%) patients; endovascular reintervention was done in 15 (6.9%) patients. The total rate of coronary events was significantly higher at 2-year follow-up (19.2% versus 7.3% at 1-year follow-up). According to coronary angiography, stented segment restenosis was 3.8 and 4.9% after one and two years, respectively. IVUSS showed that the morphological indicators characterizing late vessel luminal loss did not differ between different periods of the follow-up. Complete endothelization was observed only in 40% of endoprostheses a year after stent implantation and in 92% of endoprostheses by the end of the second year (p < 0.05).
Complete endothelization was shown by 40 and 91% of the drug-eluting stents by the end of the first and second years of the follow-up, respectively. Within the first year of the follow-up, the total number of coronary events (death + MI + recurrent angina or repeat revascularization) was significantly smaller than that within the second year.