PURPOSE

To evaluate the effect of field strength on flow-sensitive 4D magnetic resonance imaging (MRI) of the thoracic aorta. A volunteer study at 1.5 T and 3 T was conducted to compare phase-contrast MR angiography (MRA) and 3D flow visualization quality as well as quantification of aortic hemodynamics.

MATERIALS AND METHODS

Ten healthy volunteers were examined by flow-sensitive 4D MRI at both 1.5 T and 3 T MRI with identical imaging parameters (TE/TR = 6/5.1 msec, spatial/temporal resolution ≈2 mm/40.8 msec). Analysis included assessment of image quality of derived aortic 3D phase contrast (PC) angiography and 3D flow visualization (semiquantitative grading on a 0-2 scale, two blinded observers) and quantification of blood flow velocities, net flow per cardiac cycle, wall shear stress (WSS), and velocity noise.

RESULTS

Quality of 3D blood flow visualization (average grading = 1.8 ± 0.4 at 3 T vs. 1.1 ± 0.7 at 1.5 T) and the depiction of aortic lumen geometry by 3D PC-MRA (1.7 ± 0.5 vs. 1.2 ± 0.6) were significantly (P < 0.01) improved at 3 T while velocity noise was significantly higher (P < 0.01) at 1.5 T. Velocity quantification resulted in minimally altered (0.05 m/s, 3 mL/cycle and 0.01 N/m(2)) but not statistically different (P = 0.40, P = 0.39, and P = 0.82) systolic peak velocities, net flow, and WSS for 1.5 T compared to 3 T.

CONCLUSION

Flow-sensitive 4D MRI at 3 T provided improved image quality without additional artifacts related to higher fields. Imaging at 1.5 T MRI, which is more widely available, was also feasible and provided information on aortic 3D hemodynamics of moderate quality with identical performance regarding quantitative analysis.

摘要

目的

评估磁场强度对胸部主动脉四维流动敏感磁共振成像(MRI)的影响。在 1.5T 和 3T 下进行志愿者研究,比较相位对比磁共振血管造影(MRA)和 3D 血流可视化质量以及主动脉血流动力学的定量评估。

材料和方法

10 名健康志愿者在 1.5T 和 3T MRI 上进行了四维流动敏感 MRI 检查,使用相同的成像参数(TE/TR=6/5.1ms,空间/时间分辨率约为 2mm/40.8ms)。分析包括评估衍生的主动脉 3D 相位对比(PC)血管造影和 3D 血流可视化的图像质量(0-2 级的半定量评分,两位盲法观察者)以及量化血流速度、每搏心输出量、壁面切应力(WSS)和速度噪声。

结果

3D 血流可视化质量(3T 时平均评分为 1.8±0.4,1.5T 时为 1.1±0.7)和 3D PC-MRA 显示主动脉管腔几何形状(1.7±0.5 对 1.2±0.6)在 3T 时显著提高(P<0.01),而在 1.5T 时速度噪声显著升高(P<0.01)。速度定量结果表明,与 3T 相比,1.5T 的收缩期峰值速度、每搏心输出量和 WSS 仅略有改变(0.05m/s、3mL/周期和 0.01N/m2),但差异无统计学意义(P=0.40、P=0.39 和 P=0.82)。

结论

3T 下的四维流动敏感 MRI 提供了更高的图像质量,而没有与更高磁场相关的额外伪影。在更广泛应用的 1.5T MRI 下进行成像也是可行的,并提供了中等质量的主动脉 3D 血流动力学信息,在定量分析方面具有相同的性能。