Suppr超能文献

测定短时间 Synacthen 试验中 60 分钟皮质醇测量的效用。

Determining the utility of the 60 min cortisol measurement in the short synacthen test.

机构信息

Norwich Medical School, University of East Anglia, Norwich, UK.

出版信息

Clin Endocrinol (Oxf). 2013 Jul;79(1):14-9. doi: 10.1111/j.1365-2265.2012.04478.x. Epub 2013 Mar 25.

Abstract

OBJECTIVE

Despite the widespread use of the short synacthen test (SST), there remains no clear consensus on sampling times for the measurement of serum cortisol that best determines adrenal reserve. We set out to establish whether there is any value in measuring serum cortisol at 60 min following administration of synacthen.

DESIGN

Retrospective data analysis of 500 SST results measuring 0, 30 and 60 min cortisol levels after administration of 250 μg of synacthen at 2 large urban National Health Teaching Hospitals in the UK.

PATIENTS AND MEASUREMENTS

Individuals thought to have primary or secondary adrenal insufficiency given 250 μg of synacthen.

MEASUREMENTS

Serum cortisol levels measured at 0, 30 and 60 min, looking to see how many people who had adrenal insufficiency at the 30 min sample but in whom the 60 min sample showed adequate adrenal reserve.

RESULTS

The results from 384 people were analysed. A total of 276 had normal responses at 30 min and also at 60 min. A sum of 33 individuals had 'insufficient' (i.e., <550 nmol/l) 30 min cortisol levels, rising to ≥ 550 nmol/l at the 60 min test. All 75 individuals who were insufficient at 60 min were also insufficient at 30 min. No individuals passed (≥550 nmol/l) at 30 min and then failed (<550 nmol/l) at 60 min.

CONCLUSIONS

These results suggest that a significant proportion of people undergoing a SST may be inappropriately diagnosed as having adrenal insufficiency if the 60 min sample is not measured. We suggest that the 60 min sample is measured in all individuals having a SST to prevent unnecessary over-diagnosis of adrenal insufficiency.

摘要

目的

尽管短 Synacthen 试验(SST)被广泛应用,但对于最佳评估肾上腺储备功能的皮质醇血清取样时间,仍未有明确共识。我们旨在明确在 Synacthen 给药后 60 分钟测量血清皮质醇是否有价值。

设计

在英国 2 家大型城市国立教学医院,对 500 例接受 250μg Synacthen 后 0、30 和 60 分钟测量皮质醇水平的 SST 结果进行回顾性数据分析。

患者和测量指标

给予 250μg Synacthen 后,测量 0、30 和 60 分钟的血清皮质醇水平,评估哪些患者有原发性或继发性肾上腺功能不全。

测量

观察有多少在 30 分钟样本中表现为肾上腺功能不全但在 60 分钟样本中显示出足够的肾上腺储备的患者。

结果

对 384 人的结果进行了分析。共有 276 人在 30 分钟和 60 分钟时均有正常反应。有 33 人在 30 分钟时皮质醇水平“不足”(即<550nmol/L),在 60 分钟测试时升高至≥550nmol/L。所有在 60 分钟时皮质醇水平不足(<550nmol/L)的 75 人均在 30 分钟时也不足。没有患者在 30 分钟时通过(≥550nmol/L),然后在 60 分钟时失败(<550nmol/L)。

结论

这些结果表明,如果未测量 60 分钟样本,接受 SST 的患者中可能有相当一部分被不恰当地诊断为肾上腺功能不全。我们建议所有接受 SST 的患者均测量 60 分钟样本,以防止不必要的肾上腺功能不全过度诊断。