Ishaq Muhammad
Department of Cardiothoracic Surgery, Royal Infirmary of Edinburgh, United Kingdom.
Saudi J Anaesth. 2012 Apr;6(2):169-71. doi: 10.4103/1658-354X.97033.
We report a case of low cardiac output syndrome caused by dynamic left ventricular (LV) outflow obstruction after aortic valve replacement (AVR). This recognized phenomenon probably occurs more frequently than appreciated, and the author suggests that this should be considered when managing patients with severe hemodynamic instability after AVR. In addition, we also focus on the fact that invasive pacemaker systems have significant effects on cardiac output augmentation postoperatively and in long-term management of patients with LV outflow tract (LVOT) obstruction following AVR. The possible mechanisms and subsequent treatments are discussed.
我们报告一例主动脉瓣置换术(AVR)后因动态左心室(LV)流出道梗阻导致的心输出量降低综合征。这种已被认识到的现象可能比人们意识到的更频繁地发生,作者建议在处理AVR后出现严重血流动力学不稳定的患者时应考虑到这一点。此外,我们还关注到侵入性起搏器系统对术后心输出量增加以及AVR后左心室流出道(LVOT)梗阻患者的长期管理有显著影响。本文讨论了可能的机制及后续治疗方法。