Medical Physics, Institute of Physics, Carl von Ossietzky University Oldenburg, Germany.
Int J Audiol. 2012 Sep;51(9):697-707. doi: 10.3109/14992027.2012.690078. Epub 2012 Jul 4.
A review is given of internationally comparable speech-in-noise tests for hearing screening purposes that were part of the European HearCom project. This report describes the development, optimization, and evaluation of such tests for headphone and telephone presentation, using the example of the German digit triplet test. In order to achieve the highest possible comparability, language- and speaker-dependent factors in speech intelligibility should be compensated for.
The tests comprise spoken numbers in background noise and estimate the speech reception threshold (SRT), i.e. the signal-to-noise ratio (SNR) yielding 50% speech intelligibility.
The respective reference speech intelligibility functions for headphone and telephone presentation of the German version for 15 and 10 normal-hearing listeners are described by a SRT of -9.3 ± 0.2 and -6.5 ± 0.4 dB SNR, and slopes of 19.6 and 17.9%/dB, respectively. Reference speech intelligibility functions of all digit triplet tests optimized within the HearCom project allow for investigation of the comparability due to language specificities.
The optimization criteria established here should be used for similar screening tests in other languages.
对欧洲 HearCom 项目中用于听力筛查的国际可比语音噪声测试进行综述。本报告以德国数字三音节测试为例,描述了这些用于耳机和电话呈现的测试的开发、优化和评估。为了实现尽可能高的可比性,应该补偿语音可懂度中的语言和说话者相关因素。
测试包括背景噪声中的口语数字,并估计语音接收阈值(SRT),即产生 50%语音可懂度的信噪比(SNR)。
描述 15 名和 10 名正常听力受试者耳机和电话呈现的德语文本各自的参考语音可懂度函数,分别为-9.3±0.2dB SNR 和-6.5±0.4dB SNR,斜率分别为 19.6%/dB 和 17.9%/dB。在 HearCom 项目中优化的所有数字三音节测试的参考语音可懂度函数允许因语言特异性而进行可比性研究。
此处建立的优化标准应适用于其他语言的类似筛查测试。