To establish the objective, noninvasive recording of the electrically evoked amplitude modulation following response (EAMFR) for the assessment of auditory nerve function in cochlear implant candidates.
Prospective clinical study from 2007 to 2010.
Cochlear Implant Programme at the Charité-Universitätsmedizin Berlin (Germany).
Thirty-eight patients with severe-to-total bilateral sensorineural hearing impairment.
Diagnostic.
The EAMFR thresholds were correlated with the mean thresholds of the intraoperative electrically evoked compound action potential (ECAP) derived by auditory nerve response telemetry and with the subjective electrical stimulation test. The intraindividual left-right similarity of the EAMFR and ECAP thresholds was investigated in 9 bilaterally implanted patients. Additionally, the correlation between auditory performance and EAMFR thresholds was investigated.
The EAMFR auditory nerve function test produced clear responses in all patients. The EAMFR thresholds correlated significantly with the mean ECAP thresholds (r = 0.58, p < 0.01) and the subjective electrical stimulation test (r = 0.32, p < 0.05). In the bilaterally implanted patients, there was either no side difference, or the ear with the lower preoperative EAMFR threshold also was the one with the lower intraoperative mean ECAP threshold. No correlation was found between EAMFR thresholds and postoperative speech recognition scores.
These novel results support the notion that the EAMFR auditory nerve function test is a useful objective and noninvasive tool to provide information about the responsiveness of the auditory nerve to electrical stimulation in cochlear implant candidates.
建立电诱发幅度调制跟随反应(EAMFR)的客观、非侵入性记录,以评估人工耳蜗植入候选者的听神经功能。
2007 年至 2010 年的前瞻性临床研究。
柏林夏洛蒂医科大学(德国)人工耳蜗项目。
38 例严重至全双侧感觉神经性听力损失患者。
诊断。
EAMFR 阈值与术中电诱发复合动作电位(ECAP)的平均阈值相关,该阈值通过听神经反应遥测得出,并与主观电刺激测试相关。在 9 例双侧植入患者中,研究了 EAMFR 和 ECAP 阈值的个体内左右相似性。此外,还研究了听觉表现与 EAMFR 阈值之间的相关性。
EAMFR 听神经功能测试在所有患者中均产生清晰的反应。EAMFR 阈值与平均 ECAP 阈值(r = 0.58,p < 0.01)和主观电刺激测试(r = 0.32,p < 0.05)显著相关。在双侧植入患者中,要么没有侧间差异,要么术前 EAMFR 阈值较低的耳朵也具有术中平均 ECAP 阈值较低的情况。EAMFR 阈值与术后言语识别评分之间无相关性。
这些新结果支持 EAMFR 听神经功能测试是一种有用的客观、非侵入性工具的观点,它可以提供有关人工耳蜗植入候选者的听神经对电刺激反应的信息。