离子-分子反应质谱法测定 Hoffmann 清单中的有害挥发性有机化合物。

Determination of hazardous volatile organic compounds in the Hoffmann list by ion-molecule reaction mass spectrometry.

机构信息

Shanghai Mass Spectrometry Center, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China.

出版信息

Rapid Commun Mass Spectrom. 2012 Aug 30;26(16):1841-8. doi: 10.1002/rcm.6300.

Abstract

RATIONALE

Off-line gas or liquid chromatographic mass spectrometry techniques are the most widely used method for analysis of hazardous, carcinogenic volatile organic compounds (VOCs) in mainstream cigarette smoke. However, these conventional techniques can lead to modification of VOCs during sample preparation due to the high reactivity of VOCs. Thus, the development of on-line mass spectrometric methods for analysis of VOCs is desirable to circumvent this problem.

METHODS

The accurate identification of VOCs is a critical step in the analysis of cigarette smoke. Here, we use ion-molecule reaction mass spectrometry (IMR-MS) to study the behavior of standard VOCs in the Hoffmann list during this analytical procedure, and then to profile the VOCs in mainstream cigarette smoke using this on-line mass spectrometric method.

RESULTS

We first discuss and summarize the charge transfer (CT) ionization and further fragmentation of 20 standard VOCs in the Hoffmann list with the ion reagents Hg(+), Xe(+), and Kr(+). The IMR-MS instrument was then connected to a Borgwaldt-RM20H rotary smoking machine in order to study VOCs in mainstream cigarette smoke on-line. Using this procedure, more than 20 VOCs were identified by IMR-MS by comparison with experimental results obtained on standard VOCs.

CONCLUSIONS

The IMR-MS technique can potentially result in reduced molecular fragmentation during analysis of VOCs. However, significant fragmentation still occurs during IMR-MS when the ionization energy (IE) of the ion reagent is much higher than the IE of the VOC, given that excess energy is stored in the newly formed ion during CT ionization. Given that IMR-MS cannot distinguish between isobaric compounds or isomers, we summarize the possible overlapping mass peaks from these isobaric species that may be present in analyses of VOCs. Selection of the ion reagent for IMR-MS should be based on the need to ensure CT ionization of the analytes, as well as avoiding their severe fragmentation.

摘要

原理

离线气相或液相色谱质谱技术是分析主流香烟烟雾中危险致癌挥发性有机化合物(VOCs)最广泛使用的方法。然而,由于 VOCs 的高反应性,这些常规技术在样品制备过程中可能导致 VOCs 的修饰。因此,开发用于分析 VOCs 的在线质谱方法是可取的,以避免这个问题。

方法

VOCs 的准确鉴定是香烟烟雾分析的关键步骤。在这里,我们使用离子-分子反应质谱(IMR-MS)来研究 Hoffmann 清单中标准 VOCs 在分析过程中的行为,然后使用这种在线质谱方法对主流香烟烟雾中的 VOCs 进行分析。

结果

我们首先讨论和总结了 Hoffmann 清单中 20 种标准 VOCs 与离子试剂 Hg(+)、Xe(+)和 Kr(+)的电荷转移(CT)电离和进一步的碎片化。然后,将 IMR-MS 仪器连接到 Borgwaldt-RM20H 旋转吸烟机上,以便在线研究主流香烟烟雾中的 VOCs。使用这种程序,通过与标准 VOCs 获得的实验结果进行比较,通过 IMR-MS 鉴定了 20 多种 VOCs。

结论

IMR-MS 技术在分析 VOCs 时可能会导致分子碎片化减少。然而,当离子试剂的电离能(IE)远高于 VOC 的 IE 时,在 CT 电离过程中,新形成的离子中储存了多余的能量,因此 IMR-MS 仍会发生显著的碎片化。由于 IMR-MS 无法区分等质量化合物或异构体,我们总结了在 VOCs 分析中可能存在的这些等质量物质的可能重叠质量峰。对于 IMR-MS,离子试剂的选择应基于确保分析物的 CT 电离以及避免其严重碎片化的需要。