Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.
Invest Ophthalmol Vis Sci. 2012 Aug 9;53(9):5242-50. doi: 10.1167/iovs.12-9825.
The study was designed to determine trabecular meshwork (TM) stiffness and its relationship to outflow facility (C) in perfused normal human and porcine eyes.
Human and porcine eyes were perfused at pressures of 10, 20, 30, and 40 mm Hg to determine C and how outflow resistance (R = 1/C) varied with the pressure. Following perfusions, TM tissue segments were dissected and stretched uniaxially to determine the circumferential bulk Young's modulus (E). The statistical significance of difference between different groups was evaluated using a two-tailed Student's t-test or Mann-Whitney U test.
A larger E correlated with a higher C measured at 10 and 20 mm Hg (P < 0.05), and a similar trend was observed at 30 and 40 mm Hg in human eyes (n = 7). Additionally, a higher C correlated to a lower variance of R, and a stiffer TM correlated to a lower variance of R in human eyes (P < 0.05). For porcine TM, E was inversely correlated to a cross-sectional area (P < 0.003, n = 11), and its value (24.9 and 1.5 kPa; geometric mean and geometric SE) was lower than E of human TM (515 ± 136 kPa; mean ± SE) (P < 0.01). C and variance of R were not significantly different between the species.
A higher circumferential stiffness of the TM correlated with a higher outflow facility and less IOP elevation-induced variation in outflow resistance in normal human eyes, but not in porcine eyes. For future studies, these correlations need to be evaluated in glaucomatous eyes to better understand normal and abnormal TM functions.
本研究旨在确定灌流正常人和猪眼小梁网(TM)的硬度及其与流出阻力(C)的关系。
在 10、20、30 和 40mmHg 的压力下对人眼和猪眼进行灌流,以确定 C 以及流出阻力(R=1/C)如何随压力变化。灌流后,分离 TM 组织段并单向拉伸以确定环向体积杨氏模量(E)。使用双尾学生 t 检验或曼-惠特尼 U 检验评估不同组之间差异的统计学意义。
在 10 和 20mmHg 时,较大的 E 与较高的 C 相关(P<0.05),在 30 和 40mmHg 时人眼也观察到类似趋势(n=7)。此外,较高的 C 与较低的 R 方差相关,人眼中较硬的 TM 与较低的 R 方差相关(P<0.05)。对于猪 TM,E 与横截面积呈反比(P<0.003,n=11),其值(24.9 和 1.5kPa;几何平均值和几何 SE)低于人 TM 的 E(515±136kPa;平均值±SE)(P<0.01)。C 和 R 的方差在两种物种之间没有显著差异。
在正常的人眼中,TM 的环向硬度较高与较高的流出效率和较低的眼压升高引起的流出阻力变化相关,但在猪眼中并非如此。对于未来的研究,需要在青光眼眼中评估这些相关性,以更好地了解正常和异常 TM 功能。