1,2-Diarylethylenediamines as pre-column fluorescence derivatization reagents in high-performance liquid chromatographic determination of catecholamines in urine and plasma.

作者信息

Umegae Y, Nohta H, Lee M, Ohkura Y

机构信息

Faculty of Pharmaceutical Sciences, Kyushu University, Fukuoka, Japan.

出版信息

Chem Pharm Bull (Tokyo). 1990 Aug;38(8):2293-5. doi: 10.1248/cpb.38.2293.

DOI:10.1248/cpb.38.2293
PMID:2279295
Abstract

Meso- and dl-1,2-diarylethylenediamines (14 species) were evaluated for pre-column fluorescence derivatization reagents in the high-performance liquid chromatographic determination of catecholamines (norepinephrine, epinephrine and dopamine) in human urine and plasma. Of the compounds, meso-1,2-bis(4-methoxyphenyl)ethylenediamine was most preferable for all the catecholamines in terms of sensitivity and selectivity. The detection limit for each catecholamine is approximately 0.5 fmol in a 50-microliters injection volume.

摘要

相似文献

1
1,2-Diarylethylenediamines as pre-column fluorescence derivatization reagents in high-performance liquid chromatographic determination of catecholamines in urine and plasma.
Chem Pharm Bull (Tokyo). 1990 Aug;38(8):2293-5. doi: 10.1248/cpb.38.2293.
2
1,2-Diarylethylenediamines as sensitive pre-column derivatizing reagents for chemiluminescence detection of catecholamines in HPLC.
J Pharm Biomed Anal. 1995 Apr;13(4-5):645-50. doi: 10.1016/0731-7085(95)01341-h.
3
High-performance liquid chromatography of plasma catecholamines using 1,2-diphenylethylenediamine as precolumn fluorescence derivatization reagent.
J Chromatogr. 1985 Nov 8;344:61-70. doi: 10.1016/s0378-4347(00)82007-1.
4
High-performance liquid chromatographic determination of catecholamines and their precursor and metabolites in human urine and plasma by postcolumn derivatization involving chemical oxidation followed by fluorescence reaction.
Anal Biochem. 1992 Feb 1;200(2):332-8. doi: 10.1016/0003-2697(92)90474-l.
5
Analysis of plasma catecholamines by high-performance liquid chromatography with fluorescence detection: simple sample preparation for pre-column fluorescence derivatization.
J Chromatogr. 1991 Jul 5;567(2):351-8. doi: 10.1016/0378-4347(91)80141-x.
6
Sensitive high-performance liquid chromatography system with fluorometric detection of three urinary catecholamines in the same range.
Anal Biochem. 1985 May 1;146(2):283-6. doi: 10.1016/0003-2697(85)90541-x.
7
Simultaneous determination of urinary catecholamines and 5-hydroxyindoleamines by high-performance liquid chromatography with fluorescence detection.高效液相色谱-荧光检测法同时测定尿中儿茶酚胺和5-羟吲哚胺
Analyst. 1998 Feb;123(2):307-11. doi: 10.1039/a706362h.
8
A fully automated HPLC method for the determination of catecholamines in biological samples utilizing ethylenediamine condensation and peroxyoxalate chemiluminescence detection.一种利用乙二胺缩合和过氧草酸酯化学发光检测法测定生物样品中儿茶酚胺的全自动高效液相色谱法。
Biomed Chromatogr. 1994 Jan-Feb;8(1):1-8. doi: 10.1002/bmc.1130080102.
9
High-performance liquid chromatographic determination of urinary catecholamines by direct pre-column fluorescence derivatization with 1,2-diphenylethylenediamine.采用1,2-二苯乙二胺直接柱前荧光衍生化高效液相色谱法测定尿儿茶酚胺。
J Chromatogr. 1986 Jul 11;380(1):229-31. doi: 10.1016/s0378-4347(00)83649-x.
10
Simultaneous automatic determination of catecholamines and their 3-O-methyl metabolites in rat plasma by high-performance liquid chromatography using peroxyoxalate chemiluminescence reaction.采用过氧草酸酯化学发光反应,通过高效液相色谱法同时自动测定大鼠血浆中的儿茶酚胺及其3 - O - 甲基代谢产物。
Anal Biochem. 1999 May 1;269(2):386-92. doi: 10.1006/abio.1999.4043.

引用本文的文献

1
Analysis of Catecholamines and Pterins in Inborn Errors of Monoamine Neurotransmitter Metabolism-From Past to Future.浅析单胺类神经递质代谢先天性缺陷中的儿茶酚胺和喋呤-从过去到未来。
Cells. 2019 Aug 9;8(8):867. doi: 10.3390/cells8080867.
2
Augmented sensitivity to benzodiazepine in septic shock rats.脓毒症休克大鼠对苯二氮䓬类药物的敏感性增强。
Can J Anaesth. 1995 Oct;42(10):937-43. doi: 10.1007/BF03011043.