J Arthroplasty. 2012 Dec;27(10):1820-1826.e2. doi: 10.1016/j.arth.2012.04.036. Epub 2012 Jul 13.
"Trabecular Metal Cone" (TM Cone) (Zimmer, Inc, Warsaw, Ind) for reconstruction of bone loss in the proximal tibia during revision total knee arthroplasty is now optional. Forty patients were randomized to receive revision total knee arthroplasty with or without TM Cone (No TM Cone). The Anderson Orthopaedic Research Institute bone loss classification and NexGen revision system were used. Radiostereometric analysis was performed with 24 months of follow-up. Maximum total point motion: stable migration was seen in the TM Cone group. No statistically significant difference was found. Segment motion analysis at 24 months showed the same net direction of rotation for the groups around the y-, z-axis and around the x-, y-axis for translation. Tibial revision implants with TM Cone result in an early stable situation with less irregular migration pattern than revision without TM Cone.
“小梁金属锥”(TM Cone)(Zimmer,Inc,印第安纳州华沙)可用于翻修全膝关节置换术中胫骨近端骨丢失的重建,现在是可选的。40 名患者被随机分为接受 TM Cone(无 TM Cone)或不接受 TM Cone 的翻修全膝关节置换术。采用安德森矫形研究所骨丢失分类和 NexGen 翻修系统。用 24 个月的随访进行放射立体分析。最大总点运动:TM Cone 组可见稳定的迁移。没有发现统计学上的显著差异。24 个月时的节段运动分析显示,两组在 y、z 轴和 x、y 轴上的旋转方向相同,平移方向相同。胫骨翻修植入物带有 TM Cone 比没有 TM Cone 的翻修,其早期稳定情况更好,不规则迁移模式更少。