Suppr超能文献

聚四氟乙烯作为微血管减压植入材料的神经组织相容性

Neural tissue compatibility of Teflon as an implant material for microvascular decompression.

作者信息

Ammar A, Lagenaur C, Jannetta P

机构信息

Department of Neurosurgery, College of Medicine and Medical Sciences, King Faisal University, Dammam, Saudi Arabia.

出版信息

Neurosurg Rev. 1990;13(4):299-303. doi: 10.1007/BF00346368.

Abstract

Teflon is utilized in neurosurgery as well as in plastic, vascular and heart surgery. Although the effect of Teflon on different types of cells and tissues has been previously studied, we are not aware of any study in which the effect of Teflon was tested on cells of the central nervous system. We have therefore examined the tissue compatibility of spongy and fibrous Teflon by directly exposing the Teflon to dissociated cerebellar cells containing both glia and neurons in tissue culture. Daily examination of the growth of the cells adjacent to Teflon fibers using an inverted phase contrast microscope revealed that Teflon has little or no effect on the growth of these cells. When the cells are fixed after 7 days in culture and stained by the Jenner-Giemsa method, adhesion of both glia and neurons to the surface of the Teflon was seen. Attachment of neural cells to the Teflon was not extensive, as was shown by indirect immunofluorescence technique in connection with double-label staining with antiGFAP as glia marker and anti-M6 as mouse neuron marker. Thus, these experiments show that Teflon is relatively inert when used as an implant in the central nervous system.

摘要

特氟龙被应用于神经外科手术以及整形、血管和心脏手术中。尽管此前已经研究过特氟龙对不同类型细胞和组织的影响,但我们并未发现有任何研究测试过特氟龙对中枢神经系统细胞的影响。因此,我们通过在组织培养中将特氟龙直接暴露于含有神经胶质细胞和神经元的解离小脑细胞中,来检测海绵状和纤维状特氟龙的组织相容性。使用倒置相差显微镜每日观察特氟龙纤维附近细胞的生长情况,结果显示特氟龙对这些细胞的生长几乎没有影响或没有影响。当细胞在培养7天后固定并用詹纳 - 吉姆萨方法染色时,可以看到神经胶质细胞和神经元都附着在特氟龙表面。通过间接免疫荧光技术结合以抗GFAP作为神经胶质细胞标记物和抗M6作为小鼠神经元标记物的双重标记染色表明,神经细胞与特氟龙的附着并不广泛。因此,这些实验表明,当用作中枢神经系统的植入物时,特氟龙相对惰性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验