Suppr超能文献

采用动态对比增强超声评价小鼠 PC-3 前列腺癌模型中的肿瘤血管生成。

Evaluation of tumor angiogenesis in a mouse PC-3 prostate cancer model using dynamic contrast-enhanced sonography.

机构信息

Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.

出版信息

J Ultrasound Med. 2012 Aug;31(8):1223-31. doi: 10.7863/jum.2012.31.8.1223.

Abstract

OBJECTIVES

The purpose of this study was to evaluate tumor angiogenesis in a mouse xenograft model injected with human PC-3 prostate cancer cells using contrast-enhanced sonography.

METHODS

Sixteen nude mice were injected with human prostate cancer cells on the back or the flank. Contrast-enhanced sonography was performed with a 5- to 12-MHz broadband linear transducer after a 500-μL bolus injection of a sonographic contrast agent composed of lipid shells and sulfur hexafluoride. Contrast-enhanced sonograms were obtained by the pulse inversion coded harmonic technique with a low mechanical index of 0.07. A region of interest was drawn to encompass the tumor, and time-intensity curves were acquired. After fitting the curve by a gamma variate function, the maximum intensity, area under the curve for up to 50 seconds, time to peak, shape parameter, and scale parameter were derived. The tumor volume, percentage of vascular endothelial growth factor expression, and CD31-positive vessel count (microvessel density) were correlated with the parameters derived from the time-intensity curve.

RESULTS

The maximum intensity was positively correlated with the microvessel density with statistical significance (r = 0.552; P = .03). The percentage of vascular endothelial growth factor expression did not have any correlation with the parameters from the curve.

CONCLUSIONS

Contrast-enhanced sonography can reflect tumor vascularity in a prostate cancer animal model. Sonography of tumor angiogenesis may permit functional assessment of the tumor vasculature and provide an imaging biomarker for tumor responses to antiangiogenic therapies.

摘要

目的

本研究旨在通过对比增强超声评价注射人前列腺癌细胞 PC-3 的荷瘤小鼠模型中的肿瘤血管生成。

方法

将人前列腺癌细胞注射到 16 只裸鼠背部或侧腹部。注射 500μL 声诺维超声造影剂后,使用 5MHz-12MHz 宽带线阵探头行对比增强超声检查。造影剂由脂质外壳和六氟化硫组成。采用脉冲反相谐波编码技术,机械指数为 0.07,获得对比增强超声图像。在肿瘤区域画一个感兴趣区(ROI),获取时间-强度曲线。通过伽马变量函数拟合曲线,得出最大强度、50 秒内曲线下面积、达峰时间、形状参数和比例参数。将肿瘤体积、血管内皮生长因子表达百分比和 CD31 阳性血管计数(微血管密度)与时间-强度曲线的参数相关联。

结果

最大强度与微血管密度呈正相关(r=0.552,P=0.03)。血管内皮生长因子表达百分比与曲线参数无相关性。

结论

对比增强超声可反映前列腺癌动物模型中的肿瘤血管生成情况。肿瘤血管生成超声可能允许对肿瘤血管进行功能评估,并为肿瘤对抗血管生成治疗的反应提供影像学生物标志物。