• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Electrocatalytic detection of streptomycin and related antibiotics at ruthenium dioxide modified graphite--epoxy composite electrodes.

作者信息

Leech D, Wang J, Smyth M R

机构信息

Department of Chemistry, New Mexico State University, Las Cruces 88003.

出版信息

Analyst. 1990 Nov;115(11):1447-50. doi: 10.1039/an9901501447.

DOI:10.1039/an9901501447
PMID:2285154
Abstract

The application of ruthenium dioxide (RuO2) modified electrodes to the electrocatalytic detection of the saccharide-related antibiotics streptomycin, novobiocin and neomycin, at low fixed potentials, was investigated. The RuO2-modified graphite - epoxy composite electrodes give extremely stable and reproducible catalytic oxidation currents for these antibiotics at potentials as low as +0.2 V (versus Ag - AgCl). Rapid quantification at the micromolar level is therefore possible. Standard calibration graphs for streptomycin and neomycin yielded slopes of 4.43 and 0.08 nA microM-1 over the linear ranges of 1.5 x 10(-6) - 2.5 x 10(-4) and 1 x 10(-5) - 2 x 10(-3) M, respectively. Owing to its catalytic oxidation by the RuIII - RuIV couple, rather than the RuIV - RuVI transition (which catalyses the oxidation of streptomycin and neomycin), novobiocin could be detected at a lower (+0.2 V) potential, with a sensitivity of 1.31 nA microM-1. Detection limits of 1.5, 6.0 and 10 microM were obtained for streptomycin, novobiocin and neomycin, respectively. These catalytic surfaces can be renewed (by polishing), with a surface-to-surface reproducibility of 6.5% for the detection of 5 x 10(-5) M streptomycin. The analytical application of RuO2-modified carbon paste electrodes to the analysis of these antibiotics by flow injection was investigated, with a view to liquid chromatographic separation with electrochemical detection applications.

摘要

相似文献

1
Electrocatalytic detection of streptomycin and related antibiotics at ruthenium dioxide modified graphite--epoxy composite electrodes.
Analyst. 1990 Nov;115(11):1447-50. doi: 10.1039/an9901501447.
2
Catalytic oxidation and flow detection of carbohydrates at ruthenium dioxide modified electrodes.
Anal Chem. 1990 Jul 15;62(14):1413-6. doi: 10.1021/ac00213a013.
3
Ruthenium and ruthenium dioxide-modified graphite-ethylene/ propylene/diene and graphite-teflon composite electrodes as amperometric flow detectors. Application to the determination of methionine.
Fresenius J Anal Chem. 2001 Oct;371(4):507-13. doi: 10.1007/s002160101032.
4
Electrocatalytic tetracycline oxidation at a mixed-valent ruthenium oxide--ruthenium cyanide-modified glassy carbon electrode and determination of tetracyclines by liquid chromatography with electrochemical detection.
Anal Chem. 2004 Apr 15;76(8):2266-72. doi: 10.1021/ac035085b.
5
Electrocatalysis at a conducting composite electrode doped with a ruthenium(II) metallodendrimer.
Anal Chem. 2000 Jul 15;72(14):3191-5. doi: 10.1021/ac0002137.
6
Potentiometric microbiological assay of gentamicin, streptomycin, and neomycin with a carbon dioxide gas-sensing electrode.
Anal Chem. 1983 Oct;55(12):1974-7. doi: 10.1021/ac00262a032.
7
Determination of catalase-like activity in plants based on the amperometric monitoring of hydrogen peroxide consumption using a carbon paste electrode modified with ruthenium(IV) Oxide.基于使用二氧化钌修饰的碳糊电极对过氧化氢消耗进行安培监测来测定植物中的过氧化氢酶样活性。
Phytochem Anal. 2006 Jul-Aug;17(4):255-61. doi: 10.1002/pca.910.
8
Electrocatalytic amperometric determination of amitrole using a cobalt-phthalocyanine-modified carbon paste electrode.
Anal Bioanal Chem. 2002 Jul;373(4-5):277-83. doi: 10.1007/s00216-002-1345-4. Epub 2002 Jun 6.
9
Electrode materials for nitric oxide detection.
Nitric Oxide. 2000 Feb;4(1):75-84. doi: 10.1006/niox.2000.0273.
10
Electrocatalytic detection of insulin at RuOx/carbon nanotube-modified carbon electrodes.钌氧化物/碳纳米管修饰碳电极上胰岛素的电催化检测
Anal Chim Acta. 2007 Jan 2;581(1):1-6. doi: 10.1016/j.aca.2006.07.084. Epub 2006 Aug 7.