The present work seeks to evaluate the biocompatibility of experimental glass ionomer cements (GIC) prepared from niobium-calcium fluoro-alumino-silicate glass powder and two commercial GICs. The GICs were implanted into the subcutaneous connective tissue of sixty rats. The rats were sacrificed during four varying time periods: 7, 15, 30, and 60 days and histopathological examinations were then performed. The Kruskal-Wallis test was performed to evaluate any significant differences between the materials. Additionally, multiple comparisons of the mean rank were also carried out using the Dunn test (p<0.05). No significant differences were observed that one GIC was superior to the other. The tissue response for all of the GICs tested was similar in all the periods examined.

摘要

本研究旨在评估由铌钙氟铝硅酸钠玻璃粉和两种市售玻璃离子水门汀制备的实验性玻璃离子水门汀(GIC)的生物相容性。将 GIC 植入 60 只大鼠的皮下结缔组织中。在 7、15、30 和 60 天四个不同时间段处死大鼠,然后进行组织病理学检查。采用 Kruskal-Wallis 检验评估材料间是否存在显著差异。同时,采用 Dunn 检验(p<0.05)对平均秩次进行多重比较。结果发现,没有一种 GIC 明显优于另一种。在所有观察的时间段内,所有测试的 GIC 的组织反应均相似。