This study evaluated a new product for flow cytometric foetomaternal haemorrhage (FMH) quantitation, Trillium QuikQuant anti-HbF FITC kit (Trillium Diagnostics, USA), in comparison with the Millipore anti-HbF FITC method.
Blood from 67 antenatal or postpartum RhD-negative women together with 108 samples spiked with 0.2%, 0.4%, 0.6%, 2%, 4%, 5%, 6%, 8% and 10% of foetal red cells were analysed by both methods.
Results for both methods were linear to 10% foetal red cells. Analysis using the Wilcoxon test found that there was no difference between the paired results of Trillium QuikQuant and the expected values of the spiked samples (P = 0.48). In contrast, Millipore anti-HbF FITC gave statistically higher results compared with both the expected values and Trillium QuikQuant anti-HbF FITC (P = 0.0003 and P < 0.0001, respectively). The Bland-Altman plot for Trillium QuikQuant showed a mean difference of only 0.06% below the expected values, whilst Millipore was 0.13% above. The analysis time with Trillium QuikQuant was approximately 40 min, requiring significantly less hands-on time than the Millipore method that required an additional four wash steps.
Trillium QuikQuant is a new precise, accurate and rapid flow cytometric kit method for the quantitation of FMH in both the antenatal and postpartum period.
本研究评估了一种用于流式细胞术胎儿母体出血(FMH)定量的新产品,即 Trillium QuikQuant 抗 HbF FITC 试剂盒(美国 Trillium Diagnostics),并将其与 Millipore 抗 HbF FITC 方法进行了比较。
使用这两种方法分析了 67 名产前或产后 RhD 阴性妇女的血液以及 108 份分别添加了 0.2%、0.4%、0.6%、2%、4%、5%、6%、8%和 10%胎儿红细胞的样本。
两种方法的结果在 10%胎儿红细胞时均呈线性关系。使用 Wilcoxon 检验分析发现,Trillium QuikQuant 的配对结果与添加样本的预期值之间没有差异(P=0.48)。相比之下,Millipore 抗 HbF FITC 与预期值和 Trillium QuikQuant 抗 HbF FITC 相比,结果均具有统计学意义上的更高(P=0.0003 和 P<0.0001)。Trillium QuikQuant 的 Bland-Altman 图显示,其平均差值仅比预期值低 0.06%,而 Millipore 则高出 0.13%。使用 Trillium QuikQuant 的分析时间约为 40 分钟,所需的手工操作时间明显少于需要额外进行四个洗涤步骤的 Millipore 方法。
Trillium QuikQuant 是一种新的、精确、准确和快速的流式细胞术试剂盒方法,可用于产前和产后 FMH 的定量。