Suppr超能文献

单侧膝关节伸展桥测试期间横断面骨盆对线测量的可靠性

Reliability of transverse plane pelvic alignment measurement during the bridge test with unilateral knee extension.

作者信息

Andrade Juliana A, Figueiredo Luisa C, Santos Thiago R T, Paula Ana C V, Bittencourt Natália F N, Fonseca Sérgio T

机构信息

Department of Physical Therapy, School of Physical Education, Physical Therapy and Occupational Therapy, Universidade Federal de Minas Gerais-UFMG, Belo Horizonte, MG, Brazil.

出版信息

Rev Bras Fisioter. 2012 Jul-Aug;16(4):268-74.

Abstract

BACKGROUND

The bridge test with unilateral knee extension evaluates the stability of the trunk and pelvis. The evaluation of this stability can contribute to the understanding of the occurrence of musculoskeletal injuries.

OBJECTIVES

To investigate the intra- and inter-rater reliability of a qualitative analysis and intra-test reliability of a quantitative analysis of transverse plane pelvic alignment during the bridge test with unilateral knee extension.

METHOD

Thirty participants (24.73±4.24 years old) were tested. The qualitative analysis was conducted by asking two raters to judge the transverse plane pelvic alignment and its reliability was assessed with the weighted kappa coefficient (k(w)). The quantitative analysis was conducted by measuring the greatest pelvic tilt angle in transverse plane and its reliability was assessed by use of the intraclass correlation coefficient (ICC); the mean change, which was evaluated using 95% confidence interval of the mean difference (95%CI d) and Bland-Altman plot; and the quantification of measurement variability, which was assessed using standard error of measurement (SEM) and the coefficient of variation of the typical error (CVTE). In addition, the minimal detectable change (MDC₉₅) was determined.

RESULTS

The intra-rater reliability ranged from fair to moderate (k(w)=0.32 to 0.58) and the inter-rater reliability was substantial (k(w)=0.80). The intra-test reliability was excellent (ICC=0.82), the 95%CI d ranged from -0.51º to 1.99º, the SEM was 2.38° and the CV(TE) was 28.75%. The MDC₉₅ was 6.59°.

CONCLUSIONS

The inter-rater reliability was greater than the intra-rater reliability; the intra-test reliability was excellent and showed no systematic or random error.

摘要

背景

单侧膝关节伸展的桥接试验用于评估躯干和骨盆的稳定性。对这种稳定性的评估有助于理解肌肉骨骼损伤的发生情况。

目的

探讨单侧膝关节伸展桥接试验中横断面骨盆对线的定性分析的评分者内和评分者间信度以及定量分析的试验内信度。

方法

对30名参与者(24.73±4.24岁)进行测试。定性分析由两名评分者判断横断面骨盆对线情况,并使用加权kappa系数(k(w))评估其信度。定量分析通过测量横断面最大骨盆倾斜角度进行,并使用组内相关系数(ICC)评估其信度;使用平均差的95%置信区间(95%CI d)和Bland-Altman图评估平均变化;使用测量标准误(SEM)和典型误差变异系数(CVTE)评估测量变异性。此外,确定最小可检测变化(MDC₉₅)。

结果

评分者内信度从中等到中等(k(w)=0.32至0.58),评分者间信度较高(k(w)=0.80)。试验内信度优秀(ICC=0.82),95%CI d范围为-0.51°至1.99°,SEM为2.38°,CV(TE)为28.75%。MDC₉₅为6.59°。

结论

评分者间信度大于评分者内信度;试验内信度优秀,未显示系统误差或随机误差。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验