Suppr超能文献

[Fundus screening by medical technicians].

作者信息

Schütt F, Bruckner T, Schäfer K, Lehnhoff D, Rudofsky G, Kasperk C, Nawroth P, Auffarth G U

机构信息

Augenklinik, Universität Heidelberg, INF 400, 69120, Heidelberg, Deutschland.

出版信息

Ophthalmologe. 2013 Feb;110(2):154-9. doi: 10.1007/s00347-012-2649-1.

Abstract

Ocular fundus photography allows detection of both ocular and systemic diseases. This study investigated the efficacy of a broad screening in a department of internal medicine using nonmydriatic digital fundus photography. For 8 weeks a medical technician was trained in using the camera as well as interpreting the photographs. The medical technician and an ophthalmologist evaluated the fundus photographs separately by using a self-developed questionnaire. The fundus camera was user-friendly and after several weeks of adjustment and practical application the medical technician was able to detect the majority of pathological fundus photographs. Out of 218 patients examined 148 (68%) were identified as pathological by the medical technician and 163 (75%) by the ophthalmologist (p = 0.0003). The medical technician missed 15 (7%) patients. Furthermore the diagnoses made by the medical technician were faulty. In summary an ophthalmological screening by a medical technician is feasible but the diagnosis still remains the responsibility of ophthalmologists. Such a compromise could facilitate the examination of a large number of patients and disclose previously unrecognized diseases.