Zinkevich O D, Medvedev V N, Safina N A, Kharrasov A F, Muginov M A
Klin Med (Mosk). 1990 Sep;68(9):66-8.
The levels of plasma fibronectin (FN) were investigated in patients during heart surgery using artificial circulation. Plasma FN levels were assessed by electroimmunoassay (rocket immunoelectrophoresis) and bioassay (aggregation of gelatin-coated microparticles). The application of gelatinol in hemodilution++ composition led to the depletion of bioactive Fn from 140 to 0 micrograms/ml, whereas immunoreactive Fn levels were slightly elevated. The in vitro experiments have shown that gelatinol inhibits the aggregation of gelatinol-coated microparticles and chemiluminiscence of neutrophils, stimulated by gelatin-coated particles. Gelatinol elimination from hemodilution++ composition resulted in the reduction of postoperative mortality and accelerated tissue reparation.